Zoeller NE462 Owner's Manual
Zoeller NE462 Owner's Manual

Zoeller NE462 Owner's Manual

Potable water convertible jet pumps

Advertisement

Quick Links

Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
Register your
Zoeller Pump Company
Product on our website:
http://reg.zoellerpumps.com/
Potable Water Convertible Jet Pumps
Congratulations on the purchase of the Zoeller Potable Water
Convertible Jet Pump. Since 1939 the name Zoeller has represented
the standard for submersible sump and sewage pumps. The
same high-quality workmanship and easy maintenance design
has been incorporated into this line of potable water products.
This Zoeller system will provide years of trouble-free service
when installed according to the manufacturer recommendations.
Table of Contents
Safety Instructions .......................................................................... 1
Limited Warranty............................................................................. 2
Preinstallation Information ...........................................................2-3
Installation Procedures ...............................................................4-7
Parts List ......................................................................................... 7
Troubleshooting Checklist .............................................................. 8
Owner's Information
Model Number: ______________________ Date Code: _________________
Job Name: ______________________________________________________
Dealer: _________________________________________________________
Date of Purchase:
_______________________________________________
Contractor: _____________________________________________________
Date of Installation: _______________________________________________
System Readings During Operation: Voltage __________ Amps _________
MAIL TO: P .O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624
OWNER'S MANUAL
© Copyright 2015 Zoeller
This manual incorporates the installation, operation, maintenance,
and service instructions into one document to aid in the ownership of
a Zoeller potable water product. Please read and review this manual
before installing the product. Many items contained within, when
followed correctly, will not only ensure a long and problem-free life
for the system, but also save time and money during installation.
Should further assistance be necessary please call our Technical
Service department at 1-800-928-PUMP.
Safety Instructions
TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR
PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY
INSTRUCTIONS IN MANUAL AND ON PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION
AND OPERATION OF THIS UNIT AND MUST BE KEPT WITH
THE PUMP.
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the pump or in the
manual, look for one of the following signal words
and be alert to the potential for personal injury or
property damage.
Warns of hazards that WILL cause serious personal
injury, death or major property damage.
Warns of hazards that CAN cause serious personal
injury, death or major property damage.
Warns of hazards that CAN cause personal injury
CAUTION
or property damage.
Indicates special instructions which are very
important and must be followed.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS
PRIOR TO PERFORMING ANY WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
Co. All rights reserved.
®
FM2537
Supersedes
Visit our web site:
zoellerpumps.com
0415
0513

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NE462 and is the answer not in the manual?

Questions and answers

Summary of Contents for Zoeller NE462

  • Page 1 The a Zoeller potable water product. Please read and review this manual same high-quality workmanship and easy maintenance design before installing the product. Many items contained within, when has been incorporated into this line of potable water products.
  • Page 2: Limited Warranty

    Decreased pump performance and life and Reproductive Harm- www.P65warnings.ca.gov. expectancy can occur if the ground water is not cold (86 ºF/30 ºC) or contains air or gases. © Copyright 2015 Zoeller Co. All rights reserved. ®...
  • Page 3: Safety Information

    This jet pump is wired for either 115V or 230V. The label on the pump will state whether pump is pre-wired for 115V or 230V. To change pump voltage, see pump label diagram. © Copyright 2015 Zoeller Co. All rights reserved.
  • Page 4 1. To assure leak free connections, use Teflon tape or pipe dope on all switch and pipe threads. Tighten all connections by hand plus 1-1/2 additional turns. 2. Use pipe dope on external threads of all plumbing connections. © Copyright 2015 Zoeller Co. All rights reserved. ®...
  • Page 5: Tools Required

    Description Ball Valve (plastic) 3/4 in. x 1/4 in. bushing (steel) Pressure Gauge Pump stand for tank Well adapter for single pipe packer installations IL1385 IL1385 (straight and right angle shown) © Copyright 2015 Zoeller Co. All rights reserved. ®...
  • Page 6 Unions in the suction line near the pump and 4 in. ID Well well will aid in servicing. Be sure to leave enough room so that wrenches can be used easily. IL1184 Foot Valve © Copyright 2015 Zoeller Co. All rights reserved. ®...
  • Page 7 1-1/2" 1-1/4" 1-1/2" 1-1/4" 50 - 75' 1-1/4" 1-1/4" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 75 - 100' 1-1/2" 1-1/4" 1-1/2" 1-1/2" 2" 1-1/2" 100 - 150' 1-1/2" 1-1/2" 2" 1-1/2" 2" 2" © Copyright 2015 Zoeller Co. All rights reserved. ®...
  • Page 8 1. Make the connection to your well. Wrap all threaded fittings with pipe tape 5 times and then apply a pipe paste (pipe dope) to ensure an air tight connection (Fig. 1). 2. Finish the connection to your well with additional pipe and fittings as needed (Fig. 2). Tape IL1395 IL1396 IL1396 IL1395 © Copyright 2015 Zoeller Co. All rights reserved. ®...
  • Page 9 (Fig. 5). CAUTION: Install a pressure relief valve on any installation where the pump pressure can exceed the maximum working pressure of the tank. IL1389 IL1391 IL1390 IL1387 Glue IL1390 IL1387 IL1391 © Copyright 2015 Zoeller Co. All rights reserved. ®...
  • Page 10 The device is automatic and resets itself IL1401 once the temperature has dropped to a safe point. Frequent tripping of the device indicates trouble in the motor or power lines and immediate attention is needed. © Copyright 2015 Zoeller Co. All rights reserved. ®...
  • Page 11 Pull the red wire with the female flag connector from the “L2” terminal. Place it to the left on the “B” terminal space post (Fig. 11b). Reinstall the rear motor cover (Fig. 11c). NOTE: To change 1 HP models to 115V, simply reverse instructions above. © Copyright 2015 Zoeller Co. All rights reserved. ®...
  • Page 12 The pump body may need to be filled several times in order to achieve the prime (Fig. 4). IL1407 IL1409 IL1406 IL1408 Pressure gauge IL1409 IL1408 IL1406 © Copyright 2015 Zoeller Co. All rights reserved. ®...
  • Page 13: Pressure Setting

    CAUTION: Drain the entire system if there is danger of freezing. A drain plug is provided at the bottom of the pump case for this purpose. IL1409 PREVENT PUMP DAMAGE! Remove plug in freezing weather IL0345 © Copyright 2015 Zoeller Co. All rights reserved. ®...
  • Page 14 7. Replace the impeller and diffuser removed in Steps 2 & 3. 8. Reassemble the pump body to the motor and mounting bracket. © Copyright 2015 Zoeller Co. All rights reserved. ®...
  • Page 15 124330 124330 Pump Body 134121 134123 Plug 1/4” NPT Pressure Switch 020345 020345 Cap Screws, 3/8 x 3/4” Base 128034 128034 Lead Wire 136135A 136135A ( * ) Standard hardware item © Copyright 2015 Zoeller Co. All rights reserved. ®...
  • Page 16: Troubleshooting

    MAIL TO: P .O. BOX 16347 • Louisville, KY 40256-0347 SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961 Visit our web site: (502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624 zoellerpumps.com © Copyright 2015 Zoeller Co. All rights reserved. ®...

This manual is also suitable for:

Ne463462-0006463-0006

Table of Contents