PROlink Command Structure
Obtaining a Pack Low End Setting status
This is the fastest way to see the Low End Settings in a pack. The PROlink answer gives the pack
Low End trim status from the selected pack starting with the pack number, followed by the six
dimmer channels beginning with dimmer one.
Format:
Variables:
Example:
PROlink response:
Obtaining firmware version in PROlink
The PROlink version is useful if a specific Radia is to be queried for its Firmware version.
Format:
Example:
Operation Commands
Operation commands are used for real-time lighting control and setup of scenes prior to
programming presets.
Recalling Presets
If the value for <t> is not entered, the AMX Lighting controller will use the value stored at the time
the preset was recorded. The <t> parameter is optional. This is the fastest way to have many lights
change levels.
Format:
Variables:
Example 1:
PROlink response:
Example 2:
PROlink response:
Ramping Dimmers Up
The dimmer will continue ramping until the carriage return is sent or until the dimmer reaches level
zero or 100. Ramping is best done on the push, while stopping is done on the release of a button.
Format:
Variables:
Example:
PROlink response:
24
Send_String LTS, "'<p>LE?', 13"
• <p>: This is the pack number 1-10 or A (all) (Only one pack at a time)
Send_String LTS, "'1LE?', 13"
C
P01: 000, 005, 000, 000, 005, 000
SEND_STRING RADIA," <pack#> `VER', 13"
String From [96:1:1]-[$0C<pack#> VERSION #3.01$0D$0A?] -
11:53:29
Send_String LTS, "'<s>B<t>', 13"
• <s>: This is the preset number 1-128, 253, 254, 255
• <t>: This is the ramp rate, 0-255 in seconds (optional)
Send_String LTS, "'3B5', 13"
C
GOTO 003 in 005
Send_String LTS, "'3B', 13"
C
GOTO 003 in 003 (default time = 3)
Send_String LTS, "'<n>U'"
• <n>: This is the dimmer number from 1-60 or All (Any combination of dimmers)
Send_String LTS, "'1U'"
C
01 UP
no<enter>
AMX Lighting PROlink/AXlink Programming