SBP 29 Installation Manual
Transmit Transducer cable
The following transducer cables are all supplied by Kongsberg Maritime with the
SBP 29 system.
Tx transducer cables
System beamwidth
3 degrees
6 degrees
12 degrees
All Tx cables are moulded to the Cable Connection Units.
Note
* CCU = Cable Connection Unit
The length of the cables are fixed. The cables can not be extended or shortened during
installation.
Cable specifications
• Cable length: 25 m
• Maximum outer diameter: 12.95 +/– 0.5 mm
• Minimum bending radius: 77.5 mm
• Connector: 25-pin D-Sub connector
86
Number of CCUs*
4
2
1
Number of cables from
CCUs* to Tx elements
8
4
2