Kongsberg Simrad ST90 Technical Specifications
Kongsberg Simrad ST90 Technical Specifications

Kongsberg Simrad ST90 Technical Specifications

Fish-finding sonar
Hide thumbs Also See for Simrad ST90:
Table of Contents

Advertisement

Quick Links

TECHNICAL
SPECIFICATIONS
Simrad ST90
kongsberg.com/simrad

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Simrad ST90 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kongsberg Simrad ST90

  • Page 1 TECHNICAL SPECIFICATIONS Simrad ST90 kongsberg.com/simrad...
  • Page 3 Technical specifications The purpose of this publication is to present the technical specifications related to the Simrad ST90 system. These technical specifications summarize the main functional and operational characteristics of the ST90 Fish-finding sonar. They also provide information related to power requirements, physical properties and environmental conditions.
  • Page 4 Kongsberg Maritime disclaims any responsibility for damage or injury caused by improper installation, use or maintenance of the equipment. Disclaimer Kongsberg Maritime AS endeavours to ensure that all information in this document is correct and fairly stated, but does not accept liability for any errors or omissions. Support information If you require maintenance or repair, contact your local dealer.
  • Page 5: Table Of Contents

    Technical specifications Table of contents SIMRAD ST90 ................7 Important..........................8 System description ......................10 System diagram........................12 System units ........................13 Display description....................13 Processor Unit description..................14 Transceiver Unit description ..................15 Hull Unit description ....................16 Transducer description ...................17 Installation trunk description..................19 Additional required and optional items................20 Installation trunk requirement ................20...
  • Page 6 Simrad ST90 Operating Panel power requirements (Mk2) ............39 Operating Panel power requirements (Mk3) ............39 Transceiver Unit power requirements ..............39 Hull Unit power requirements ................40 Weights and outline dimensions ..................41 Display weight and outline dimensions..............41 Enix Processor Unit weight and outline dimensions..........41 Operating Panel weight and outline dimensions (Mk1) .........42...
  • Page 7 Technical specifications 381457 Transceiver dimensions (Mk1/Old) ..............77 447567 Hull Unit dimensions ST92 ................80 435546 Hull Unit dimensions ST93 ................83 447545 Hull Unit dimensions ST94 ................86 436691 Installation trunk dimensions................89 207485 Blind flange dimensions (ø760 mm)..............92 439413 Installation trunk extender (350 mm) ..............93 374676 Installation trunk extender (180 mm) ..............96 082973 Mounting flange DN500 ..................99 083045 Gate valve installation DN500................102...
  • Page 8 Simrad ST90 110-0035138/A...
  • Page 9: Simrad St90

    Simrad ST90 Simrad ST90 Topics Important, page 8 System description, page 10 System diagram, page 12 System units, page 13 Additional required and optional items, page 20 Scope of supply, page 23 Order information, page 24 General safety rules, page 25...
  • Page 10: Important

    Simrad ST90 Technical specifications Important The ST90 is an advanced product. It is used with other advanced products. There is important information that you need to know. Watertight integrity The size, location and design of the sonar room must fulfil all the requirements to the vessel’s watertight integrity.
  • Page 11 Simrad ST90 Caution You must never turn on the ST90 system when the ship is in dry dock. The transducer can be damaged if it transmits in the open air. When the ST90 system is not used When you do not use the ST90 system, turn it off.
  • Page 12: System Description

    • Do not damage the transducer cables. Avoid exposure to sharp objects. System description The Simrad ST90 is a long range and low frequency fish finding sonar with a 360 degrees coverage. The ST90 system is designed for medium and large sized fishing vessels.
  • Page 13 The ST90 system is equipped with the celebrated signal processing software developed by Kongsberg Maritime. This includes Hyperbolic FM (HFM) transmissions. This pulse type is also known as "chirp". It ensures a clutter free picture with very high resolution in range.
  • Page 14: System Diagram

    Simrad ST90 Technical specifications System diagram The system diagram identifies the main components of a basic ST90 system. Only the main connections between the units are shown. Detailed interface capabilities and power cables are not shown. Display (The second display is optional.)
  • Page 15: System Units

    The display is not a standard part of the delivery. This is a commercial item that can be purchased locally. Kongsberg Maritime may provide a suitable display. The chosen display must be designed for maritime use, and it must meet the minimum performance specifications.
  • Page 16: Processor Unit Description

    Simrad ST90 Technical specifications Processor Unit description A dedicated maritime computer is provided. In this publication, the computer can also be referred to as the Processor Unit, and vice versa. The Processor Unit is a rugged and powerful computer. It is designed for long life in a demanding maritime environment.
  • Page 17: Transceiver Unit Description

    Transceiver Unit. The heat exchanger also inhibits dust and dirt particles from entering the transceiver. The heat exchanger is powered from 230 VAC using a separate outlet. Related topics Simrad ST90, page 7 System units, page 13 110-0035138/A...
  • Page 18: Hull Unit Description

    Simrad ST90 Technical specifications Hull Unit description The hull unit is used to lower the transducer down below the ship’s hull when the ST90 system shall be used. When the ST90 system is turned off, the transducer is hoisted for protection.
  • Page 19: Transducer Description

    Related topics Simrad ST90, page 7 System units, page 13 Transducer description The cylindrical transducer allows the sonar beam to provide a full 360 degrees coverage of the water volume.
  • Page 20 Simrad ST90 Technical specifications Note The transducer is covered with a thick red or black protective coating made of a special plastic type. The protective coating is a vital part of the transducer. It is very important that neither this coating nor the internal parts of the transducer are damaged during the handling, installation or cleaning.
  • Page 21: Installation Trunk Description

    The installation trunk - with a blind flange - can be ordered from Kongsberg Maritime as an optional delivery. As an alternative, the installation trunk can be manufactured by the shipyard based on the drawings in this manual.
  • Page 22: Additional Required And Optional Items

    The installation trunk - with a blind flange - can be ordered from Kongsberg Maritime as an optional delivery. As an alternative, the installation trunk can be manufactured by the shipyard based on the drawings in this manual.
  • Page 23: Speed Log Requirement

    Simrad ST90 Speed log requirement In order to operate correctly, the ST90 system requires input from a speed log. Unless specified in the contract, a speed log is not a part of the ST90 system delivery. Provided that a speed log sensor is interfaced to the ST90 system, the vessel’s current speed can be presented in the user interface.
  • Page 24: Operating Panel Option

    Simrad ST90 Technical specifications To choose the best power solution for your installation, consider environmental conditions, the physical space available, the availability and duration of the batteries, and the power requirements of the ST90 system. Operating Panel option The optional Operating Panel contains all necessary control functions for normal operation of the ST90 system.
  • Page 25: Scope Of Supply

    Additional items are required for operation. These items must be added to the ST90 system for full operational functionality. Some items are optional. Such items can be purchased from Kongsberg Maritime or obtained locally.
  • Page 26: Order Information

    Simrad ST90 Technical specifications Order information To order the ST90 system, or any of the optional items provided with it, contact your local dealer. If you do not have a regular dealer, a list of all our distributors and dealers can be found on our website.Your dealer will also be able to help you with a detailed...
  • Page 27: General Safety Rules

    Simrad ST90 General safety rules Safety is important. The safety precautions must be followed at all times during installation and maintenance work. WARNING The ST90 system operates on 115 VAC and/or 230 VAC at 50/60 Hz. This voltage is lethal! You must never work alone on high-voltage equipment! The hull unit is powered by a 3-phase high voltage.
  • Page 28 Simrad ST90 Technical specifications Cables Each electric cable must be handled carefully. This is important to avoid damage to the cable. This is also important to avoid electric shock in the event that the cable is unintentionally connected to a power source.
  • Page 29: Installation Requirements

    Simrad ST90 Installation requirements Topics Supply voltage requirements, page 27 Uninterruptible power supply (UPS) requirements, page 27 Cables and wiring requirements, page 28 Compass deviation requirements, page 28 Noise sources, page 28 Dry docking requirements, page 29 Requirement for classification approval, page 29 Supply voltage requirements The supply voltage must kept within ±10% of the installation’s nominal voltage.
  • Page 30: Cables And Wiring Requirements

    Simrad ST90 Technical specifications The minimum requirements for the uninterruptible power supply (UPS) are: • : The input voltage must fit vessel supply voltage. Input voltage • : 230 VAC, 50 Hz Output voltage • Output power – Processor Unit + Display: 1000 W –...
  • Page 31: Dry Docking Requirements

    If a ST90 system is connected to a local area network, data security is important. Equipment manufactured by Kongsberg Maritime is frequently connected to the vessel's local area network (LAN). When you connect a computer to a local area network you will always expose the data on that computer.
  • Page 32: Support Information

    The damage done if a remote computer succeeds doing this. Kongsberg Maritime has no information regarding the complete system installation on any vessel. Systems provided by Kongsberg Maritime are regarded as stand-alone offline systems. They are stand-alone even though they may be connected to a network for sensor interfaces and/or data distribution.
  • Page 33 Telefax • www.kongsberg.com/simrad Website • simrad.france@simrad.com Email address • : Kongsberg Underwater Technology LLC (KUTL) / Simrad Fisheries Company name • : 19210 33rd Ave W, Suite A, Lynnwood, WA 98036, USA Address • : +1 425 712 1136 Telephone •...
  • Page 34 Simrad ST90 Technical specifications • : +65 6411 7488 Telephone • : +60 3 2201 3359 Telefax • www.kongsberg.com/simrad Website • simrad.asia@simrad.com Email address Korea • : Kongsberg Maritime Korea Ltd Company name • : #1101 Harbor Tower, 113-1, Nampodong 6-Ga, Jung-Gu,...
  • Page 35: Technical Specifications

    Technical specifications Technical specifications Topics Introduction to technical specifications, page 34 Performance specifications, page 34 Power requirements, page 38 Weights and outline dimensions, page 41 Environmental requirements, page 45 Compass safe distance, page 48 Minimum display requirements, page 50 110-0035138/A...
  • Page 36: Introduction To Technical Specifications

    ST90 Fish-finding sonar. They also provide information related to power requirements, physical properties and environmental conditions. Note At Kongsberg Maritime, we are continuously working to improve the quality and performance of our products. The technical specifications may be changed without prior notice.
  • Page 37 Technical specifications Note The tilt limits depend on the opening angle of the vertical beam. This means that you may not always be permitted to select the maximum specified tilt limits. Transmission • : 384 Number of transmitter channels • Horizontal TX Sector: Maximum Other options...
  • Page 38 Simrad ST90 Technical specifications – FM Correlation filter – Target Threshold Echo presentations • : 1280 x 1024 pixels (Minimum). The visual quality of the Display resolution presentation depends on the quality of your graphic adapter and display. We recommend that you use a large display with resolution 1920 x 1080.
  • Page 39 Technical specifications – You can use a Microsoft Xbox Controller to make basic adjustments to the sonar operation. • : The text in the menu buttons in the user interface can be provided Menu languages in several different languages. With a few exceptions, the chosen language is also used for all other texts.
  • Page 40: Power Requirements

    Hull Unit power requirements, page 40 Display power requirements Not applicable. The display is not a part of the ST90 scope of supply. It is not manufactured by Kongsberg Maritime. For more information, refer to the end-user documentation provided by the manufacturer. Related topics...
  • Page 41: Operating Panel Power Requirements (Mk2)

    Technical specifications Related topics Technical specifications, page 33 Power requirements, page 38 Operating Panel power requirements (Mk2) • : ST90 Operating Panel (Mk2) Make and model • : 115/230 VAC, 47 to 63 Hz, single phase, nominal Voltage requirement • : 15% Maximum voltage deviation •...
  • Page 42: Hull Unit Power Requirements

    Simrad ST90 Technical specifications Hull Unit power requirements • : ST90 Hull Unit Make • : All models Model • : 230/380/440 VAC Voltage requirement (47 to 63 Hz/3–phase/Nominal voltage) • Maximum voltage deviation – 230 VAC: 15% – 380/440 VAC: 340 to 485 VAC •...
  • Page 43: Weights And Outline Dimensions

    Display weight and outline dimensions Not applicable. The display is not a part of the ST90 scope of supply. It is not manufactured by Kongsberg Maritime. For more information, refer to the end-user documentation provided by the manufacturer. Related topics...
  • Page 44: Operating Panel Weight And Outline Dimensions (Mk1)

    Simrad ST90 Technical specifications Operating Panel weight and outline dimensions (Mk1) • : ST90 Operating Panel Mk1 Make and model • Outline dimensions: – : 165 mm Depth – : 385 mm Width – : 51 mm Height • : 4 kg (Approximately)
  • Page 45: Transceiver Unit Weight And Outline Dimensions

    Technical specifications Transceiver Unit weight and outline dimensions A new transceiver cabinet was introduced in late 2022. The new cabinet is identified as Mk2. The new cabinet is slightly wider than the Mk1 version. To identify which version you have, observe the order number in your order confirmation, or the part number on the cabinet's identification label.
  • Page 46: Related Topics

    Simrad ST90 Technical specifications – : 2518 mm Height above the installation trunk – : 1065 kg (Approximately) Weight • : ST94 Model – : 4268 mm Total height – : 3018 mm Height above the installation trunk – : 1115 kg (Approximately)
  • Page 47: Environmental Requirements

    Hull Unit environmental requirements, page 47 Display environmental requirements Not applicable. The display is not a part of the ST90 scope of supply. It is not manufactured by Kongsberg Maritime. For more information, refer to the end-user documentation provided by the manufacturer. Related topics...
  • Page 48: Operating Panel Environmental Requirements (Mk1)

    Simrad ST90 Technical specifications Related topics Technical specifications, page 33 Environmental requirements, page 45 Operating Panel environmental requirements (Mk1) Operating Panel • : ST90 Operating Panel Mk1 Make and model • : 0 to +50 °C Operating temperature • : -40 to 70 °C Storage temperature •...
  • Page 49: Transceiver Unit Environmental Requirements

    Technical specifications • : 5 to 95% relative, non-condensing Relative humidity • : IP65 Ingress protection (IP) code Related topics Technical specifications, page 33 Environmental requirements, page 45 Transceiver Unit environmental requirements • : ST90 Transceiver Unit Make and model •...
  • Page 50: Compass Safe Distance

    Hull Unit compass safe distance, page 49 Display compass safe distance Not applicable. The display is not a part of the ST90 scope of supply. It is not manufactured by Kongsberg Maritime. For more information, refer to the end-user documentation provided by the manufacturer. Related topics...
  • Page 51: Operating Panel Compass Safe Distance (Mk2)

    Technical specifications • : 30 cm Standard compass • : 20 cm Other compass Related topics Technical specifications, page 33 Compass safe distance, page 48 Operating Panel compass safe distance (Mk2) • : ST90 Operating Panel Mk2 Make and model •...
  • Page 52: Minimum Display Requirements

    Simrad ST90 Technical specifications Related topics Technical specifications, page 33 Compass safe distance, page 48 Minimum display requirements Unless specifically ordered, the ST90 system is not provided with a display. The display must then be purchased locally. You can use more than one display on your Processor Unit depending on personal and/or operational preferences.
  • Page 53: Drawing File

    Drawing file Drawing file Topics About the drawings in the drawing file, page 52 385609 Processor Unit outline dimensions Enix, page 53 494024 Processor Unit outline dimensions (HT20470/DC), page 57 494025 Processor Unit outline dimensions (HT20470/AC), page 60 204688 Operating Panel dimensions (Mk1), page 63 443179 Operating Panel dimensions (Mk2), page 65 440689 Operating Panel cut‑out drawing (Mk2), page 68 439594 Operating Panel adapter plate (Mk2), page 69...
  • Page 54: About The Drawings In The Drawing File

    Simrad ST90 Technical specifications About the drawings in the drawing file Relevant drawings related to the installation and/or maintenance of the ST90 system are provided for information purposes only. Note These drawings are provided only for information and planning purposes. Information may be omitted.
  • Page 55: 385609 Processor Unit Outline Dimensions Enix

    Drawing file 385609 Processor Unit outline dimensions Enix Download the source drawing from our website: https://www.kongsberg.com/st90 110-0035138/A...
  • Page 56 Simrad ST90 Technical specifications 110-0035138/A...
  • Page 57 Drawing file 110-0035138/A...
  • Page 58 Simrad ST90 Technical specifications Related topics Drawing file, page 51 110-0035138/A...
  • Page 59: 494024 Processor Unit Outline Dimensions (Ht20470/Dc)

    Drawing file 494024 Processor Unit outline dimensions (HT20470/DC) Download the source drawing from our website: https://www.kongsberg.com/st90 110-0035138/A...
  • Page 60 Simrad ST90 Technical specifications 110-0035138/A...
  • Page 61 Drawing file Related topics Drawing file, page 51 110-0035138/A...
  • Page 62: 494025 Processor Unit Outline Dimensions (Ht20470/Ac)

    Simrad ST90 Technical specifications 494025 Processor Unit outline dimensions (HT20470/AC) Download the source drawing from our website: https://www.kongsberg.com/st90 110-0035138/A...
  • Page 63 Drawing file 110-0035138/A...
  • Page 64 Simrad ST90 Technical specifications Related topics Drawing file, page 51 110-0035138/A...
  • Page 65: 204688 Operating Panel Dimensions (Mk1)

    Drawing file 204688 Operating Panel dimensions (Mk1) Download the source drawing from our website: https://www.kongsberg.com/st90 110-0035138/A...
  • Page 66 Simrad ST90 Technical specifications Related topics Drawing file, page 51 110-0035138/A...
  • Page 67: 443179 Operating Panel Dimensions (Mk2)

    Drawing file 443179 Operating Panel dimensions (Mk2) Download the source drawing from our website: https://www.kongsberg.com/st90 110-0035138/A...
  • Page 68 Simrad ST90 Technical specifications 110-0035138/A...
  • Page 69 Drawing file Related topics Drawing file, page 51 110-0035138/A...
  • Page 70: 440689 Operating Panel Cut-Out Drawing (Mk2)

    Simrad ST90 Technical specifications 440689 Operating Panel cut‑out drawing (Mk2) Download the source drawing from our website: https://www.kongsberg.com/st90 Related topics Drawing file, page 51 110-0035138/A...
  • Page 71: 439594 Operating Panel Adapter Plate (Mk2)

    Drawing file 439594 Operating Panel adapter plate (Mk2) Download the source drawing from our website: https://www.kongsberg.com/st90 110-0035138/A...
  • Page 72 Simrad ST90 Technical specifications Related topics Drawing file, page 51 110-0035138/A...
  • Page 73: 476352 Operating Panel Dimensions (Mk3)

    Drawing file 476352 Operating Panel dimensions (Mk3) Download the source drawing from our website: https://www.kongsberg.com/st90 110-0035138/A...
  • Page 74 Simrad ST90 Technical specifications 110-0035138/A...
  • Page 75 Drawing file Related topics Drawing file, page 51 110-0035138/A...
  • Page 76: 489582 Transceiver Dimensions (Mk2)

    Simrad ST90 Technical specifications 489582 Transceiver dimensions (Mk2) Download the source drawing from our website: https://www.kongsberg.com/st90 110-0035138/A...
  • Page 77 Drawing file 110-0035138/A...
  • Page 78 Simrad ST90 Technical specifications Related topics Drawing file, page 51 110-0035138/A...
  • Page 79: 381457 Transceiver Dimensions (Mk1/Old)

    Drawing file 381457 Transceiver dimensions (Mk1/Old) Download the source drawing from our website: https://www.kongsberg.com/st90 110-0035138/A...
  • Page 80 Simrad ST90 Technical specifications 110-0035138/A...
  • Page 81 Drawing file Related topics Drawing file, page 51 110-0035138/A...
  • Page 82: 447567 Hull Unit Dimensions St92

    Simrad ST90 Technical specifications 447567 Hull Unit dimensions ST92 Download the source drawing from our website: https://www.kongsberg.com/st90 110-0035138/A...
  • Page 83 Drawing file 110-0035138/A...
  • Page 84 Simrad ST90 Technical specifications Related topics Drawing file, page 51 110-0035138/A...
  • Page 85: 435546 Hull Unit Dimensions St93

    Drawing file 435546 Hull Unit dimensions ST93 Download the source drawing from our website: https://www.kongsberg.com/st90 110-0035138/A...
  • Page 86 Simrad ST90 Technical specifications 110-0035138/A...
  • Page 87 Drawing file Related topics Drawing file, page 51 110-0035138/A...
  • Page 88: 447545 Hull Unit Dimensions St94

    Simrad ST90 Technical specifications 447545 Hull Unit dimensions ST94 Download the source drawing from our website: https://www.kongsberg.com/st90 110-0035138/A...
  • Page 89 Drawing file 110-0035138/A...
  • Page 90 Simrad ST90 Technical specifications Related topics Drawing file, page 51 110-0035138/A...
  • Page 91: 436691 Installation Trunk Dimensions

    Drawing file 436691 Installation trunk dimensions Download the source drawing from our website: https://www.kongsberg.com/st90 110-0035138/A...
  • Page 92 Simrad ST90 Technical specifications 110-0035138/A...
  • Page 93 Drawing file Related topics Drawing file, page 51 110-0035138/A...
  • Page 94: 207485 Blind Flange Dimensions (Ø760 Mm)

    Simrad ST90 Technical specifications 207485 Blind flange dimensions (ø760 mm) Download the source drawing from our website: https://www.kongsberg.com/st90 Related topics Drawing file, page 51 110-0035138/A...
  • Page 95: 439413 Installation Trunk Extender (350 Mm)

    Drawing file 439413 Installation trunk extender (350 Download the source drawing from our website: https://www.kongsberg.com/st90 110-0035138/A...
  • Page 96 Simrad ST90 Technical specifications 110-0035138/A...
  • Page 97 Drawing file Related topics Drawing file, page 51 110-0035138/A...
  • Page 98: 374676 Installation Trunk Extender (180 Mm)

    Simrad ST90 Technical specifications 374676 Installation trunk extender (180 Download the source drawing from our website: https://www.kongsberg.com/st90 110-0035138/A...
  • Page 99 Drawing file 110-0035138/A...
  • Page 100 Simrad ST90 Technical specifications Related topics Drawing file, page 51 110-0035138/A...
  • Page 101: 082973 Mounting Flange Dn500

    Drawing file 082973 Mounting flange DN500 Download the source drawing from our website: https://www.kongsberg.com/st90 110-0035138/A...
  • Page 102 Simrad ST90 Technical specifications 110-0035138/A...
  • Page 103 Drawing file Related topics Drawing file, page 51 110-0035138/A...
  • Page 104: 083045 Gate Valve Installation Dn500

    Simrad ST90 Technical specifications 083045 Gate valve installation DN500 Download the source drawing from our website: https://www.kongsberg.com/st90 110-0035138/A...
  • Page 105 Drawing file Related topics Drawing file, page 51 110-0035138/A...
  • Page 106: 33498 Gate Valve Dimensions Dn500

    Simrad ST90 Technical specifications 33498 Gate valve dimensions DN500 To obtain the source drawing, contact the manufacturer. 110-0035138/A...
  • Page 107 Drawing file 110-0035138/A...
  • Page 108 Simrad ST90 Technical specifications Related topics Drawing file, page 51 110-0035138/A...
  • Page 109: 37357 Gate Valve Dimensions Dn500

    Drawing file 37357 Gate valve dimensions DN500 To obtain the source drawing, contact the manufacturer. 110-0035138/A...
  • Page 110 Simrad ST90 Technical specifications 110-0035138/A...
  • Page 111 Drawing file Related topics Drawing file, page 51 110-0035138/A...
  • Page 112: Datagram Formats

    Simrad ST90 Technical specifications Datagram formats The ST90 system can send and receive information to and from several different peripherals. All transmissions take place as datagrams with data sentences. Each datagram has a defined format and length. The most common standard is NMEA 0183. The National Marine Electronics...
  • Page 113 Index Index Operating Panel (Mk3)........49 Processor Unit..........48 about transceiver ..........49 drawings........... 52 Transceiver Unit ......... 49 About the drawings in the drawing file ....52 CSD (compass safe distance) ac mains power technical specifications........48 requirements ..........38 CSD (Compass Safe Distance) approval display .............
  • Page 114 Simrad ST90 Technical specifications description ..........13 dimensions ..........41 gate valve DN500 environmental requirements......45 dimensions ........102, 104, 107 minimum requirements ......... 50 outline dimensions......102, 104, 107 outline dimensions........41 general safety rules ......... 25 power requirements........38 Global Positioning System (GPS) weight .............
  • Page 115 42, 71 power requirements........39 weight (Mk3) ..........42 Operating Panel adapter plate (Mk2) Kongsberg Maritime outline dimensions........69 support ............ 30 Operating Panel compass safe distance (Mk1) ..48 Operating Panel compass safe distance (Mk2) ..49 Operating Panel compass safe distance (Mk3) ..
  • Page 116 Simrad ST90 Technical specifications Enix ............53 gyro compass ..........21 gate valve DN500......102, 104, 107 heading sensor..........21 HT20470 (AC version)........60 installation trunk ......... 20 HT20470 (DC version)........57 speed log ..........21 Hull Unit ..........43 uninterruptible power supply......
  • Page 117 Index environmental requirements......45 power consumption........39 outline dimensions........41 power requirements........39 performance ..........34 weight ............. 43 specifications Transceiver Unit compass safe distance ....49 weight ............. 41 Transceiver Unit environmental requirements ..47 speed log Transceiver Unit power requirements....39 description ..........
  • Page 118 ©2023 Kongsberg Maritime ISBN N/A...

Table of Contents