Table 4-12 Parameter Description - Huawei OceanStor S2600 Routine Maintenance

Hide thumbs Also See for OceanStor S2600:
Table of Contents

Advertisement

4 Routine Maintenance Guide of the ISM

Table 4-12 Parameter Description

Parameter
Name
RAID ID
Level
Disk Type
Total
Capacity
Free Capacity The parameter indicates the free capacity of disks in a RAID group, and the
Health Status
Running
Status
Number of
Disks
----End
Exception Handling
l
l
l
l
If the fault persists, contact technical support engineers.
4-18
Description
The parameter indicates the name of a RAID group.
The RAID group ID.
The parameter indicates the RAID level. The value can be RAID 0, RAID
1, RAID 5, RAID 6, and RAID 10.
The parameter indicates the disk types in the RAID group: SAS and
SATA.
The parameter indicates the capacity of the disks in a RAID group, and the
unit is GB.
unit is GB.
RThe parameter indicates the status of the functions and running
specifications of the RAID group.
Normal: It indicates that the functions of the RAID group are properly
l
and all the parameters are set correctly.
Fault: It indicates that the RAID group cannot work properly or the RAID
l
group cannot work. The failure cannot be recovered.
Degrade: It indicates that the RAID group can work properly and all
l
functions are enabled, but the performance is not the best.
The parameter indicates the running status of a RAID group, and the status
can be Online or Offline.
The parameter indicates the number of disks in the RAID group.
If the running status of the RAID group is Offline, see the relevant alarm and remove the
fault according to the troubleshooting suggestions under the alarm.
If the health status of the RAID group is Fault, see the
fault" in the OceanStor S2600 Storage System Event Reference.
If the health status of the RAID group is Degrade, see the
degraded" in the OceanStor S2600 Storage System Event Reference or see the
RAID
Group" in the OceanStor S2600 Storage System Troubleshooting.
If a new alarm related to the RAID group is displayed on the alarm interface, click the alarm
and remove the fault according to the troubleshooting suggestions under the alarm.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
OceanStor S2600 Storage System
Routine Maintenance
"0x200190389 RAID group
"0x200190388 RAID group
"Degraded
Issue 01 (2009-09-27)