4 Routine Maintenance Guide of the ISM
Step 5 Click the battery icon on the controller enclosure or right-click the battery icon. In the displayed
shortcut menu, choose Properties,and then the system displays BBU Properties dialog box.
Step 6 The parameters of viewing UPS information are described, as shown in

Table 4-3 Parameter descriptions

Parameter
BBU ID
Enclosure ID
Health Status
Running
Status
Current
voltage
Charge
Status
----End
Exception Handling
l
l
l
l
If the fault persists, contact technical support engineers.

4.4 Checking the Status of the UPS

This section describes how to check the UPS through the ISM.
Reference Standard
l
4-6
Description
The parameter indicates the BBU ID. The BBU on the left is BBU 0 and that
on the right is BBU 1.
The ID of the controller enclosure where the BBU is located.
The parameter indicates the status of the functions and running specifications
of the BBU.
Normal: It indicates that the functions of the BBU and all the parameters
l
are set correctly.
Fault: It indicates that the BBU work abnormally or the BBU cannot work.
l
The failure cannot be recovered.
The parameter indicates the running status of the BBU. The status can be
Present or Absent.
The parameter indicates the current voltage of the BBU, and the unit is V.
The charge status of the BBU is listed as follows:
Full: It indicates the BBU is fully charged.
l
Not Full: It indicates the BBU is not fully charged.
l
If the running status of the BBU is Absent, ensure that the BBU is normally inserted.
If the health status of the BBU is Fault, see the
S2600 Storage System Event Reference.
If a new alarm related to the BBU is displayed on the alarm interface, click the alarm and
remove the fault according to the troubleshooting suggestions under the alarm.
No new alarms related to the UPS are displayed on the alarm interface.