Table 4-4 Parameter Description - Huawei OceanStor S2600 Routine Maintenance

Hide thumbs Also See for OceanStor S2600:
Table of Contents

Advertisement

OceanStor S2600 Storage System
Routine Maintenance
l
Procedure
Step 1 Log in to the ISM.
Step 2 In the navigation tree, click the Physical tab.
Step 3 In the operation area, click the Device Figure tab.
Step 4 Click the UPS icon or right-click the UPS icon. On the displayed shortcut menu, choose
Properties, and then the UPS Properties dialog box is displayed.
Step 5 The parameters of viewing UPS information are described, as shown in

Table 4-4 Parameter Description

Parameter
ID
Health Status
Running
Status
Charge
Status
Discharge
Status
Whether
meets the
disk-writing
requirements
Remaining
Service Time
Version
Protocol
Version
Issue 01 (2009-09-27)
The health status of the UPS is Normal and the running status is Online.
NOTE
The BBU is disabled by the system when the BBU and UPS are configured at the same time.
Description
The parameter indicates the UPS ID. The UPS on the left is UPS 00 and that
on the right is UPS 01.
The parameter indicates the functions of the UPS and the performance of the
running parameter. The status can be Normal, Degraded, and Faulty.
The parameter indicates the running status of the UPS. The status can be
Online, Offline, and Faulty.
The parameter indicates the charging state of the UPS. There are the following
options:
Charged: It indicates that charging the UPS is not complete.
l
Floatingly Charged: It indicates that charging the UPS is complete but
l
the UPS is not removed from the socket.
Invalid: It indicates that the system cannot determine the current charging
l
state of the UPS.
The parameter indicates the discharge status of the UPS. The status can be
Discharging and No Discharged.
The parameter indicates whether the feeding duration of the UPS can ensure
that the dirty data in the cache can be written to the vault. There are two
options: Yes and No.
The parameter indicates the remaining service life of the UPS.
It is calculated as follows:
Remaining service life = 1150 - number of used days
The parameter indicates the version of the UPS.
The parameter indicates the protocol version of the UPS.