Programming the Mio R-4
"^" Button Commands (Cont.)
^GLL
Change the
bargraph lower
limit
^GRD
Change the
bargraph
ramp-down time
in 1/10th of a
second
^GRU
Change the
bargraph
ramp-up time in
1/10th of a
second
^GSC
Change the
bargraph slider
color or joystick
cursor color
60
Change the bargraph lower limit.
Syntax:
"'^GLL-<vt addr range>,<bargraph low>'"
Variable:
• variable text address range = 1 - 4000.
• bargraph limit range = 1 - 65535 (bargraph lower limit range).
Example:
SEND_COMMAND Device,"'^GLL-500,150'"
Changes the bargraph lower limit to 150.
Change the bargraph ramp-down time in 1/10th of a second.
Syntax:
"'^GRD-<vt addr range>,<bargraph ramp down time>'"
Variable:
• variable text address range = 1 - 4000.
• bargraph ramp down time = In 1/10th of a second intervals.
Example:
SEND_COMMAND Device,"'^GRD-500,200'"
Changes the bargraph ramp down time to 20 seconds.
Change the bargraph ramp-up time in 1/10th of a second.
Syntax:
"'^GRU-<vt addr range>,<bargraph ramp up time>'"
Variable:
• variable text address range = 1 - 4000.
• bargraph ramp up time = In 1/10th of a second intervals.
Example:
SEND_COMMAND Device,"'^GRU-500,100'"
Changes the bargraph ramp up time to 10 seconds.
Change the bargraph slider color or joystick cursor color. A user can also assign the color
by Name and R,G,B value (RRGGBB or RRGGBBAA).
Syntax:
"'^GSC-<vt addr range>,<color value>'"
Variable:
• variable text address range = 1 - 4000.
• color value = Refer to theRGB Values for all 88 Basic Colors table on page 35.
Example:
SEND_COMMAND Device,"'^GSC-500,12'"
Changes the bargraph or joystick slider color to Yellow.