Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Kemper Manuals
Industrial Equipment
FK-5
Operating instructions manual
Kemper FK-5 Operating Instructions Manual
Break tank station
Hide thumbs
Also See for FK-5
:
Operating instructions manual
(164 pages)
,
Service manual
(134 pages)
,
Installation instructions manual
(60 pages)
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
page
of
56
Go
/
56
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Safety Instructions
Main Menu
System Settings
Language
Date
Time
Error Signal
Battery Change
Factory Settings
Pump
Error Messages
Inlet Control
Operating Modes
Cleaning
Flush Inlet Pipe
Clean Tank
USB Menu
Battery Change
Error Messages
Advertisement
Quick Links
Download this manual
Operating instructions for FK-5
Break Tank Station, Fig. 369
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the FK-5 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for Kemper FK-5
Tank Equipment Kemper FK-5 Operating Instructions Manual
Break tank station (164 pages)
Home Automation Kemper FK-5 Service Manual
Break tank station (134 pages)
Water System Kemper FK-5 Operating Instructions Manual
Break tank station (88 pages)
Safety Equipment Kemper FK-5 Service Manual
Break tank station (88 pages)
Tank Equipment Kemper FK-5 Installation Instructions Manual
Break tank station (60 pages)
Water System Kemper FK-5 Installation Instructions Manual
Break tank station (60 pages)
Safety Equipment Kemper FK-5 Operating Instructions Manual
Break tank station (56 pages)
Tank Equipment Kemper FK-5 Installation Instructions Manual
(32 pages)
Industrial Equipment Kemper FK-5 Maintenance Instruction
Break tank station (28 pages)
Control Unit Kemper FK-5 Installation Instructions Manual
(12 pages)
Industrial Equipment Kemper FK-5 PRO Operating Instructions Manual
Break tank station (180 pages)
Industrial Equipment Kemper TRESOR Installation And Operating Instructions Manual
Stainless steel built-in wall cabinet (16 pages)
Industrial Equipment Kemper MINI-TRESOR Installation And Operating Instructions Manual
Stainless steel built-in wall cabinet (36 pages)
Industrial Equipment Kemper EVOLUTION LINE Operating Manual
Roll machine (204 pages)
Industrial Equipment Kemper 712 99 001 Installation And Operating Instructions
Automatic backwash figure (4 pages)
Industrial Equipment Kemper MINI-TRESOR Installation And Operating Instructions Manual
Stainless steel built-in wall cabinet (16 pages)
Summary of Contents for Kemper FK-5
Page 1
Operating instructions for FK-5 Break Tank Station, Fig. 369...
Page 2: Table Of Contents
Pressure stage PN 10, Outlet pump pressure Error messages | 8.0 DN 20: 4.3 bar/0.43 MPa DN 25: 5.9 bar/0.59 MPa DU value: DN 20: 0.83 l/s DN 25: 1.67 l/s 2 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 3: Safety Instructions
The KEMPER FK-5 Break Tank Station is used for out repair or maintenance work. separating potable from non-potable water Danger! Only specialists with electrical installations if fluid category 5 according to DIN EN 1717 / DIN 1988-100.
Page 4
The programmed flushing processes are still carried out. Automatic mode Bypasses the “Time mode” weekly program. Time limit Switches temporarily to automatic mode until the preset time has elapsed. Back Start screen Active area 4 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 5
00:00 - 00:00 Tuesday 00:00 - 00:00 Wednesday 00:00 - 00:00 down Thursday 00:00 - 00:00 Friday 00:00 - 00:00 left Saturday 00:00 - 00:00 Sunday 00:00 - 00:00 right Confirm entry © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 5 / 56...
Page 6: Main Menu
FK-5 | DN 25 Main menu 1. System settings 2. Pump 3. Error messages 4. Empty tank 5. Inlet control 6 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 7: Language
English Date 23.07.2016 Time 11:07:48 Time change Auto Rain water usage set Container cleaning set Overflow monitoring Key press signal Error signal 10. Battery change 11. Factory menu 12. Factory settings © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 7/ 56...
Page 8: Pump
1. System settings 2. Pump 3. Error messages 4. Empty tank 5. Inlet control 1.2.1 Preset by the factory. Pump 1. Cut-in pressure 2.0 bar 2. Set 3. Relay cycles 8 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 9
1.2.2 +10 m = +1 bar 60 m 6.3 bar 20 m 2.3 bar 0.3 bar Cut-in pressure Min: 0.3-Actual: 2.0bar - Max: 6.0 bar © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 9 / 56...
Page 10
1.2.3 Pump 1. Cut-in pressure 2.0 bar 2. Set 3. Relay cycles 1.2.4 Reset the counter Reset the counter? 10 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 11
1.2.5 Reset the counter Counter deleted! © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 11 / 56...
Page 12
4. Empty tank 5. Inlet control 1.3.1 Error code [0001] - [0025]. Error messages 25.04.2016 12:16:45 [0019] Error temperature measurement out of range 29.04.2016 15:03:57 [0015] Level below measuring range Pump pressure 12 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 13: Error Messages
5. Inlet control 1.4.1 Empty tank Inlets closed Solenoid valve On/Off Pump controller Stop Main menu 1. System settings 2. Pump 3. Error messages 4. Empty tank 5. Inlet control © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 13 / 56...
Page 14
1.4.2 KEMPER Fig. 369 02 14 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 15
1.4.2 Auto Start © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 15 / 56...
Page 16
1.4.3 Auto 5 cm 1.4.4 G 3 / 4 " 16 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 17: Inlet Control
Main menu 1. System settings 2. Pump 3. Error messages 4. Empty tank 5. Inlet control Only if “Rainwater Utilisation Unit” is active. 1.5.1 Inlet control Inlet 1 Inlet 2 Automatic © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 17 / 56...
Page 18: Operating Modes
FK-5 | DN 25 Operating modes Time Mode Standby Automatic Plant off 18 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 19
Operating times Monday 00:00 - 00:00 Tuesday 00:00 - 00:00 Wednesday 00:00 - 00:00 Thursday 00:00 - 00:00 Friday 00:00 - 00:00 Saturday 00:00 - 00:00 Sunday 00:00 - 00:00 © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 19 / 56...
Page 20
2.1.4 Operating times Monday 00:00 - 00:00 Tuesday 00:00 - 00:00 Wednesday 00:00 - 00:00 Thursday 00:00 - 00:00 Friday 00:00 - 00:00 Saturday 00:00 - 00:00 Sunday 00:00 - 00:00 20/ 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 21
Operating times Monday 00:00 - 00:00 Tuesday 00:00 - 00:00 Wednesday 00:00 - 00:00 Thursday 00:00 - 00:00 Friday 00:00 - 00:00 Saturday 00:00 - 00:00 Sunday 00:00 - 00:00 © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 21 / 56...
Page 22
Operating times Monday 00:00 - 00:00 Tuesday 08:35 - 00:00 Wednesday 00:00 - 00:00 Thursday 00:00 - 00:00 Friday 00:00 - 00:00 Saturday 00:00 - 00:00 Sunday 00:00 - 00:00 22 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 23
Tuesday 08:35 - 16:25 Wednesday 00:00 - 00:00 Thursday 00:00 - 00:00 Friday 00:00 - 00:00 Saturday 00:00 - 00:00 Sunday 00:00 - 00:00 2. 1 .2 2. 1 .10 © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 23 / 56...
Page 24
2.2.1 FK-5 | DN 25 2.2.2 Operating modes Time Mode Standby Automatic mode Plant off 24 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 25
2.2.3 Automatic mode Permanently On Temporary 2.2.4 Automatic mode Automatic switch to time mode after: 000:00:00h Start Settings © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 25 / 56...
Page 26
2.2.5 Set time limit Min:0- Actual:0h - Max:999 2.2.6 Automatic mode Automatic switch to time mode after: 024:00:00h Start Settings 26 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 27
2.2.7 Automatic mode Automatic switch to time mode after: 023:59:59h Permanently On Temporary © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 27 / 56...
Page 28: Cleaning
Betriebszeiten FK-5 | DN 25 Cleaning Flush inlet pipe Clean tank 28 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 29: Flush Inlet Pipe
3.1.1 Flush inlet pipe Inlet 1 Inlet 2 *) Only if “Rainwater Utilisation Unit” is active. 3.1.2 Flush inlet 1 Automatic flushing Set automatic Deactivate flushing Flush manually © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 29 / 56...
Page 30
Automatic flushing inlet 1 Monday 00:00 0 min Tuesday 00:00 0 min Wednesday 00:00 0 min Thursday 00:00 0 min Friday 00:00 0 min Saturday 00:00 0 min Sunday 00:00 0 min 30 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 31
0 min Tuesday 00:00 0 min Wednesday 00:00 0 min Thursday 00:00 0 min Friday 00:00 0 min Saturday 00:00 0 min Sunday 00:00 0 min 3.1.6 Automatic flushing inlet 1 © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 31 / 56...
Page 32
00:00 0 min Tuesday 00:00 0 min Wednesday 00:00 0 min Thursday 00:00 0 min Friday 00:00 0 min Saturday 00:00 0 min Sunday 00:00 0 min 3.1.8 Start time: 32 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 33
0 min Friday 00:00 0 min Saturday 00:00 0 min Sunday 00:00 0 min 3. 1 . 1 0 DIN EN 806-5 VDI/DVGW 6023 Flushing duration Min: 0-Actual: 1Min - Max360 © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 33 / 56...
Page 34: Clean Tank
00:00 0 min Friday 00:00 0 min Saturday 00:00 0 min Sunday 00:00 0 min 3.1.3 3.1.11 Cleaning Flush inlet pipe Clean tank Only if “Tank Cleaning Unit” is active. 34 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 35
2. Start cleaning Cleaning agent must comply with DVGW W 291 / W 319. No foaming! 3.2.2 Exposure time Min: 0-Actual: 1h - Max: 10 Adjust expose time depending on cleaning agent. © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 35 / 56...
Page 36
Have the cleaning agent ready. 1. Set the exposure time 2. Start cleaning 3.2.4 Tank cleaning Select inlet for tank cleaning. Inlet 1 Inlet 2 Only if “Rainwater Utilisation Unit” is active. 36 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 37
3.2.5 Tank cleaning Please remove the cover. Tank cleaning Cleaning Cancel cleaning? Flush inlet pipe Clean tank © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 37 / 56...
Page 38
3.2.6 Tank cleaning Please add cleaning product. 3.2.7 Tank cleaning Exposure time active Time expired in: 00:59:59 The device is blocked for the duration of the application time. 38 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 39
Flush out the cleaning agent using the pressure pipe. 3.2.8 Tank cleaning Unable to end the flushing process successfully! Ensure that the cleaning product is safely and reliably removed from the tank. +49 2761 891-800 ServiceGT@kemper-olpe.de © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 39 / 56...
Page 40
FK-5 | DN 25 Dosage The current operating data is shown as a graph. 40 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 41
Consumption data 12 days 3 months 6 months 1 year Reset the counter 6 months Consumption data Please wait. Creating a graphic. © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 41 / 56...
Page 42: Usb Menu
> 2 MB | FAT 32 formatting. USB Menu Save fault log Save consumption log Save short-term log Firmware update Press OK to save the log on the USB stick. 42 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 43
5.1.1 Save Logbook Log data successfully saved! 5.1.2 © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 43 / 56...
Page 44
You can find updates at www.kemper-olpe.de under Building Technology in the service download area. > 2 MB | FAT 32 formatting. 44 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 45
USB Menu Update in progress! Save fault log Mark used blocks... Save consumption log Erase used blocks... Save short-term log Write Flash... Firmware update Update complete! Please remove the USB Stick! © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 45 / 56...
Page 46: Battery Change
Battery change required. Battery low. Follow operating instructions. 46 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 47
© www.kemper-olpe.de – 10.2020 / K410036900025-00 – 47 / 56...
Page 48
Before you touch the circuit board, make sure that you are not conducting an electrostatic charge! Li-Ion 18650 1800mAh | 3,6V Only use high-quality batteries from brand manufacturers. 48 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 49
Click © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 49 / 56...
Page 50: Error Messages
FK-5 | DN 25 Main menu 1. System settings 2. Pump 3. Error messages 4. Empty tank 5. Inlet control 50 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 51
7.10 System settings 6. Overflow monitoring 7. Key press signal 8. Error signal 9. Battery change 10. Factory menu 7.11 Battery change Please confirm change of battery. © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 51 / 56...
Page 52
If the level sensor is clogged, remove the level sensor and clean if necessary. If the level sensor is not clogged, call the Kemper customer service. 52 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 53
Give the battery time to charge. power to close the servo drives. Replace battery. Frequent closing of the servo drives due to power cuts without sufficient battery charging time. Battery faulty © www.kemper-olpe.de – 10.2020 / K410036900025-00 – 53 / 56...
Page 54
54/ 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
Page 55
© www.kemper-olpe.de – 10.2020 / K410036900025-00 – 55 / 56...
Page 56
Gebr. Kemper GmbH + Co. KG Service-Hotline +49 2761 891-800 Harkortstraße 5 www.kemper-olpe.de D-57462 Olpe info@kemper-olpe.de 56 / 56 – K410036900025-00 / 10.2020 – © www.kemper-olpe.de...
This manual is also suitable for:
369 06
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the FK-5 and is the answer not in the manual?
Questions and answers