Top Panel Interface - Datalogic S70 Series Manual

Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies
Hide thumbs Also See for S70 Series:
Table of Contents

Advertisement

TOP PANEL INTERFACE

Opening the dust cover provides access to the top panel interface. The top panel interface consists of the RUN/PRG/ADJ
mode switch, LO/DO switch, +/SET/- Navigation key, dual red/green digital displays, and output LED.
RUN/PRG/ADJ Mode Switch
The RUN/PRG/ADJ mode switch puts the sensor in RUN, PRG (Program), or ADJ (Adjust) mode.
RUN mode allows the sensor to operate normally and prevents unintentional programming changes via
the +/SET/- button. PRG mode allows the sensor to be programmed through the display driven
programming menu (see Program Mode below).
ADJ mode allows the user to perform Expert TEACH/SET methods and Manual Adjust (see Adjust
Mode below).
LO/DO Switch
The LO/DO switch is used to select Light Operate or Dark Operate mode. In Light Operate mode, the
output is ON when the sensing condition is above the threshold (for Window SET, the output is ON
when the sensing condition is inside the window). In Dark Operate mode, the output is ON when the
sensing condition is below the threshold (for Window SET, the output is ON when the sensing condition
is outside the window).
+/SET/- Navigation key
The +/SET/- Navigation key is a 3-way button. The +/- positions are engaged by rocking the button left/
right.
The SET position is engaged by clicking down the button while the rocker is in the middle position. All
three button positions are used during PRG mode to navigate the display driven programming menu.
During ADJ mode, SET is used to perform TEACH/SET methods and +/- are used to manually adjust
the threshold(s). The Navigation key is disabled during RUN mode, except when using Window SET,
see
Window SET.
Red/Green Digital Displays
During RUN and ADJ mode, the Red display shows the signal level and the Green display shows the
threshold.
During PRG mode, both displays are used to navigate the display driven programming menu.
Output LED
The output LED provides a visible indication when the output is activated.
Remote Input / IO-Link
For more information about how to perform TEACH/SET methods, to program the sensor remotely,
or to interface with the sensor via IO-Link, see the www.datalogic.com.
Run Mode
Run mode allows the sensor to operate normally and prevents unintentional programming changes.
The +/SET/- Navigation key is disabled during RUN mode, except when using Window SET, see
Window
3
SET.