5.5

Diagnostic Display KCU02

LED
Color / status
H49
Safety
H52.1
E-stop
H52.2
Power Supply
H52.3
Warning
NOTICE
Do not connect and disconnect live connections.
Fig.5-16:
LEDs on KCU02
Significance
Green
Signals without error
Red
Signals with error
(Error is saved until device is switched
off.)
Off
E-stop not activated
Red
E-stop active (/E_Stop)
Green
Supply unit without error, regular status
Red
Supply unit signals error (/Bb_V)
Green
Supply unit without warning (/Warn), reg‐
ular status
Red
Supply unit signals warning
Bosch Rexroth AG
Risk of damage to the drive controller by con‐
necting and disconnecting live connections!
Measures
None
Check wiring of safety technology for
short-circuit.
Deactivate E-stop, if necessary
Activate E-stop, if necessary (see con‐
nection point X50)
None
Check power supply, see also "F2086
Error supply module"
None
Check supply unit, see also "E2086 Pre‐
warning supply module overload"
43/69