5.3.3

Position of Connection Points

Figure
Element Significance
1
Equipment grounding con‐
ductor
2
Joint bar of equipment
grounding conductor
F4
Fuse for output X54 (L+)
F5
Fuse for output X54 (L-)
LEDs
H49: Safety
H52.1: E-Stop
H52.2: Power Supply
H52.3: Warning
H52.4: DC Bus In
H52.5: Drives
H53: 42 V Out
H54: DC Bus Out
24 V, 0 V Control voltage
L+, L-
DC bus
X1
Module bus
X29.1
Multi-Ethernet
X29.2
X49
Safety technology
X50
E-Stop
X52
Status messages
X53
42 V, 0 V
X54
DC bus, equipment ground‐
ing conductor
Fig.5-8:
KCU02 connection points
Bosch Rexroth AG
Instructions for Use
Notes
For connection to the equipment grounding
system
For connection to neighboring device
(part of basic accessory HAS01)
30 A
30 A
See index entry "KCU02 → LEDs"
For connection to supply unit via contact bars
(part of basic accessory HAS01)
For connection to supply unit via contact bars
(part of basic accessory HAS01)
Keep ribbon cable in parking position, when
there is no connection to neighboring device.
Signals are looped through
L3 (Safe Torque Off)
E-Stop input
For exchanging status messages
42 V output; control voltage supply
DC bus output; power supply
35/69

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth kcu02.1n-et-et*-025-nn-n-nn-nw