2.2 Installation
(1) The heat pump unit must be installed by professional technicians. Otherwise unit may be damaged or
body injured, even dead.
(2) The unit designed for outdoor location with good ventilation. Recirculation of cold discharge air back
into evaporator coil will greatly reduce heating capacity and efficiency of the unit, which will avoid the
compessor warranty.
(3) The unit can be installed almost anywhere in the outdoors. To get a good performance, it needs to meet
the three factors:
a) Good ventilation
b) Stable and reliable power supply
c) Recycled water system
The difference from gas water heater, it should not bring environmental pollution or have the installing
problems in-windy areas.
(4) The unit should not be installed in a limited air ventilation area, or placed in a bush where it will block
the air inlet. These location deny the unit of a continuous source of fresh air. When seasons changing,
it may stick leaves on the evaporator coil, thereby reducing its efficiency and impact of its service life.
(5) For indoor installation, please consult more instructions from technicians.
(6) When install a bypass, it should be not exceed 30 % of nominal flow rate
(7) Must make Water level higher than the circulation pump location.
(8) Below picture show the minimum required distance on each side of pool heat pump unit.