Download Print this page

Brilix XHPFDPLUS60 User Manual page 12

Swimming pool heat pump

Advertisement

Model:
XHPFDPLUS140 &
COMPRESSOR
R WHT
C RED
YLW/GRN
C2
BLU
YLW/GRN
L
N
220-240V ~ 50Hz
3-XPDLT0022S
Note: Electrical connection
The power supply for the heat pump must come, preferably, from an exclusive circuit with regulatory
protection components (30mA differential protection) and a magneto-thermal switch.
- The electrical installation must be carried out by a specialized professional (electrician) in accordance
with the standards and regulations in force in the country of installation.
- The heat pump circuit must be connected to a safety earth circuit at the terminal block.
XHPFDPLUS160
C1
FAN MOTOR
WHT
YLW/GRN
BLK
OUT2
BRN
4
3
BLU
OUT3
RED
OUT4
OUT5
2
2
BLU
AC-N
CN2
CN1
PE
SWITCH
(Water Pump)
* The dotted line part are only used in some models
5
OUT1
4
3
CN5
BRN
RED
Transformer
3
12
11
RUN/POW
2
Ambient temperature
2
Back temperature
2
Heating pipe temperature
2
Water out temperature
2
Water in temperature
CN4
SW1

Hide quick links:

Advertisement