Parameter 0
To set the entering water temp.
under cooling mode (15-35 °C,
default setting: 28 °C)
Parameter 3
Terms of Entry defrosting
function (-30 °C to 0 °C, default
setting -7 °C)
Parameter 6
Mode : 0 Cool 1 Heat and
Cool 2 Heat and cool + auxiliary
elec. Heating 3 Heat default
setting: 1 Heat and Cool
Remarks:
For the XHP series ,
Mode default setting : 3. Heat
Parameter 1
To set the entering water temp.
under heating mode (15-40 °C,
default setting:28 °C)
Parameter 4
Terms of Exit defrosting
function (2 to 30 °C, default
setting 20 °C)
Parameter 7
Mode selection of Electronic
expansion valve ( 0 to 1),
default setting 1 (auto)
14
16
Parameter 2
Total working time of compressor
after frosting (30-90 min,default
setting : 40 min)
Parameter 5
Time of Exit defrosting (1 to 12
min, default setting 12 min)
Parameter 8
Heating target for superheat
(-15 °C-15 °C) default
setting: 3 °C