5.9 RUNNING DATA SETTINGS
ATTENTION:
•HP running parameters must be checked after installation and before first used.
•When the LED on, it will display water inlet temperature.
•When the LED off, it will display the actual time
•When the LED on, the water temp could be changed.
Parameter Meaning
0
To set the entering water temp under cooling mode
1
To set the entering water temp under heating mode
2
Entry into defrosting time period
3
Terms of Entry defrosting function
4
Terms of Exit defrosting function
5
Time of Entry defrosting
Mode: 0 Cool 1 Heat and Cool 2 Heat and Cool +
6
auxiliary elec heating 3 Heat
7
Mode selection of Electronic expansion valve
8
Superheat for heating target
9
Superheat for cooling target
Manual adjustment steps of electronic expansion
A
valve
B
Inlet water temperature
C
Outlet water temperature
D
Condenser temperature under heating mode
E
Gas return temperature
F
Ambient temperature
G
Condenser temperature under Cooling mode
H
Actual steps of electronic expansion valve
Range
Defaul
15 - 35 °C
15 - 40 °C
30 - 90 min
-30 °C to 0 °C
2 to 30 °C
1 to12 min
0 - 3
0 - 1
-15 °C - 15 °C
-15 °C - 15 °C
18 - 94
-9 - 99 °C
-9 - 99 °C
-9 - 99 °C
-9 - 99 °C
-9 - 99 °C
-
N * 5
17
19
Remarks
28 °C
Adjustable
28 °C
Adjustable
40 min
-7 °C
20 °C
12 min
For the XHP series ,
1
Mode default setting :
3. Heat
1
(auto)
3 °C
-2 °C
70
Exact testing by
value
Exact testing by
value
Exact testing by
value
Exact testing by
value
Exact testing by
value
Exact testing by
value