Operator's Manual Supplement
Contents
About this Supplement .......................................... 1
SpeedDome Ultra VII EIS Features ...................... 1
Menu Programming Navigation............................. 2
Setting Up EIS....................................................... 2
Programming Sequences...................................... 4
DirectSet Menu...................................................... 8
Specifications-Indoor Dome ................................ 13
Declarations ........................................................ 15
© 2005 Sensormatic Electronics Corp.
SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME CONFIGURATION UTILITY
OPERATOR'S MANUAL SUPPLEMENT
®
Ultra VII EIS

About this Supplement

This supplement provides detailed information
about SpeedDome Ultra VII with EIS (Electronic
Image Stabilization) camera dome features that are
not currently covered in your operator's manual.
This supplement supports information found in the
Day/Night Camera Dome Configuration Utility
Operator's Manual, 8200-0184-04.
NOTE:
Keep this supplement with your operator's
manual for reference purposes.
If you need assistance...
Contact your Sales Representative.
SpeedDome Ultra VII EIS
Features
EIS (Electronic Image Stabilization) technology
works to overcome unsteady or blurred video
images from camera movement caused by wind,
vibration, and similar conditions.
The SpeedDome Ultra VII with EIS provides the
following features with firmware version 0710-
0532-0202 and newer.
• Electronic Image Stabilization
• 16 Sequences
• Up to 16 Patterns
• Ability to change camera functions for each
Preset.
Updated information is also provided for
SensorNet, RS-422, Manchester, and UTC matrix
switchers and controllers.
1 of 15
8200-0184-13, REV. A

Advertisement

Table of Contents
loading

Summary of Contents for American Dynamics SpeedDome Ultra VII EIS

  • Page 1: Table Of Contents

    Specifications-Indoor Dome ... 13 Specifications-23X Camera with EIS ... 14 Declarations ... 15 © 2005 Sensormatic Electronics Corp. SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME CONFIGURATION UTILITY OPERATOR’S MANUAL SUPPLEMENT About this Supplement This supplement provides detailed information about SpeedDome Ultra VII with EIS (Electronic Image Stabilization) camera dome features that are not currently covered in your operator’s manual.
  • Page 2: Menu Programming Navigation

    Follow the steps below: 1. Access the Dome Configuration Menu (Figure 1) by pressing Iris Open, Focus Far and Zoom Out on your controller. SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME CONFIGURATION UTILITY OPERATOR’S MANUAL SUPPLEMENT Figure 1 DOME CONFIGURATION MENU...
  • Page 3: Changing Camera Functions Within Presets

    PRIVACY ZONES PRESETS SCAN LIMITS EXIT SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME CONFIGURATION UTILITY OPERATOR’S MANUAL SUPPLEMENT 3. Use the joystick to highlight Presets and press Focus Far to select. The Select Preset To Program screen appears (Figure 5).
  • Page 4: Return To Auto After Calling A Preset

    Sync Opts and Press Focus Far to select. The Pan / Tilt / Zoom / Sync Opts screen appears (Figure 8). SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME CONFIGURATION UTILITY OPERATOR’S MANUAL SUPPLEMENT Figure 8 PAN / TILT / ZOOM / SYNC OPTS...
  • Page 5 3. Use the joystick to highlight Presets and press Focus Far to select. The Select Preset to Program screen appears (Figure 12.). SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME CONFIGURATION UTILITY OPERATOR’S MANUAL SUPPLEMENT Figure 12. SELECT PRESET TO PROGRAM...
  • Page 6 2. Use the joystick to highlight Alarms / Areas / Home / Presets / PZ and Press Focus Far to select. The Alarms / Areas / Home / Presets/PZ screen appears (Figure 15.). SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME CONFIGURATION UTILITY OPERATOR’S MANUAL SUPPLEMENT Figure 15. ALARMS/AREAS/HOME/PRESETS/PZ...
  • Page 7: Pattern Options: Fixed Or Variable Speed

    2. Use the joystick to highlight On-Screen Text Display and press Focus Far to select. The On-Screen Text Display screen appears (Figure 18.). SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME CONFIGURATION UTILITY OPERATOR’S MANUAL SUPPLEMENT Figure 18. ON-SCREEN TEXT DISPLAY...
  • Page 8: Directset Menu

    This allows you to change or activate features without starting the dome configuration menu. See the following examples of the DirectSet menu (Figure 20). SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME CONFIGURATION UTILITY OPERATOR’S MANUAL SUPPLEMENT Figure 20: Day/Night Camera Dome DirectSet Menu (4 screens)
  • Page 9 15+DirectSet Smooth Scan: Initiates a smooth 360° clockwise rotation around the dome axis using the current tilt, zoom and focus settings. SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME CONFIGURATION UTILITY OPERATOR’S MANUAL SUPPLEMENT Command Description 16+DirectSet Stepped Scan: Initiates a...
  • Page 10: Speeddome Vii With Eis Compatibility

    None RCSN422 AD32/VM32 RCSN422 (ver 1.02) None RCSN422 AD32E/VM32E RCSN422 (ver 1.02) ADMP48 (Plus) None SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME CONFIGURATION UTILITY OPERATOR’S MANUAL SUPPLEMENT Protocol Presets Manchester RS-422 (Duplex) RS-422 (Simplex/Duplex) Manchester RS-422 (Duplex) RS-422 (Simplex/Duplex) Manchester...
  • Page 11 RCSN422 (ver 1.02) AD168¹ MP48¹ AD1024 Matrix¹ Intellex VM96TT¹ RS422 Dome¹ VM16/ADTT16 VM16E/ADTT16E USB CCTV Module (ADACSNET) SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME CONFIGURATION UTILITY OPERATOR’S MANUAL SUPPLEMENT Protocol Presets SensorNet SensorNet-V AD UTC RS-422 (Duplex/Simplex) SensorNet RS-422 (Duplex) RS-422 (Simplex)
  • Page 12 RCSN422 (ver. 1.02) ... F 0701-2814-0102, E 0701-9070-0100 VM1 ... Rev. M VM32/AD32 ... F 0701-2493-0104, E 0701-2492-0101 VM32E/AD32E ... F 0701-2836-0102, E 0701-2835-0100 VM8 ... 0701-0088-0101 VM96 ... v5.20 SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME CONFIGURATION UTILITY OPERATOR’S MANUAL SUPPLEMENT Protocol RS-422 (Duplex) SensorNet SensorNet...
  • Page 13: Specifications-Indoor Dome

    128 Kbytes of SRAM Menu Languages English, French, German, Spanish, Italian, and Portuguese SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME CONFIGURATION UTILITY OPERATOR’S MANUAL SUPPLEMENT Electrical Input Voltage ... 18-30Vac, 50/60 Hz Design Tolerance ... 16-36Vac, 50/60 Hz Power Consumption...16W max.
  • Page 14: Specifications-23X Camera With Eis

    Bubbles: RUCLR (Clear)... f0 RUSLV (Silver)... f1.5 to f2 RUSMK (Smoke)... f0.5 RUGLD (Gold)... f1.5 to f2 SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME CONFIGURATION UTILITY OPERATOR’S MANUAL SUPPLEMENT Specifications-23X Camera with EIS Type ... Interline transfer 1/4in CCD array Scanning Area...
  • Page 15: Declarations

    Sensormatic Electronics Corporation, the party responsible for FCC compliance, could void the user's authority to operate the equipment and could create a hazardous condition. SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME CONFIGURATION UTILITY OPERATOR’S MANUAL SUPPLEMENT Other Declarations Thank you for using American Dynamics products. We support our products through an extensive and worldwide network of dealers.

Table of Contents