American Dynamics MegaPower 3200 Installation Manual
American Dynamics MegaPower 3200 Installation Manual

American Dynamics MegaPower 3200 Installation Manual

Matrix switching bays scalable switcher/control cctv system
Hide thumbs Also See for MegaPower 3200:

Advertisement

Matrix Switching Bays
®
for the MegaPower
3200
Scalable Switcher/Control
CCTV System
AD2010N/P and AD2020N/P
Installation Guide
8200-0421-08 B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MegaPower 3200 and is the answer not in the manual?

Questions and answers

Summary of Contents for American Dynamics MegaPower 3200

  • Page 1 Matrix Switching Bays ® for the MegaPower 3200 Scalable Switcher/Control CCTV System AD2010N/P and AD2020N/P Installation Guide 8200-0421-08 B...
  • Page 3: Table Of Contents

    Matrix Switching Bay (Front View) Matrix Switching Bay (Rear View) Customer Service Thank you for using American Dynamics products. We support our products through an extensive worldwide network of dealers. The dealer through whom you originally purchased this product is your point of contact if you need service or support.
  • Page 4: Important Information

    Important Information This product should be installed by qualified service personnel and conform to all local codes. WARNING: RISK OF ELECTRIC SHOCK! DO NOT OPEN! No user-serviceable parts are inside. Refer servicing and adjustment to qualified service personnel. WARNING: To reduce the risk of fire or shock hazard, do not expose this product to rain or moisture.
  • Page 5: Glossary Of Terms

    Connections • Set jumpers in plug-in modules before making system connections. • System connections require good grade, 75-ohm, RG-59U video cable (Belden 8241 or equivalent) with BNC connectors. Complete all connections before applying power. • Terminate all video outputs at the last bay in the run to 75 ohms.
  • Page 6: Power Supply Module

    Note: Refer to the Glossary of Terms on page 3 while reading this section. The MegaPower 3200 matrix switching bay system can switch one of up to 3200 video inputs (typically from cameras) to one of up to 256 video outputs (typically to monitors).
  • Page 7 Figure 4. Maximum 3200 video inputs x 256 video outputs (13 camera groups x 16 monitor levels) Product Code: ADMPR3200-256N Components used: • 208 Bays (Configuration using 16 mixed bays and 192 dedicated bays controlled by 4 AD Data Lines) •...
  • Page 8 VOMs: A VOM, as directed by the keyboard, acts as a secondary switch by selecting which of its four video outputs (A, B, C, or D) connects to the video input selected by the VIM of a camera group. A VOM: •...
  • Page 9: Physical Diagram

    Figure 7. Path of video input (4-bay system using 1 VOM, 1008 inputs x 4 outputs) Physical Diagram Bay 2 (CG 2) Bay 4 Bay 3 (CG 3) Camera Group 4 Functional Block Diagram BAY 1 (Camera Group 1) VIMs (Primary Switch) Circuit Panel...
  • Page 10: Control Inputs

    Buffer monitor selection, titles, and time and date. VIMs • Controls up to 13 camera groups (3200 video inputs) and up to four monitor levels (64 video outputs). IMPORTANT! For dome PTZ control, each...
  • Page 11: Power Supply Module

    Power Supply Module The AD2010PS power supply module converts ac to dc which powers the bay. Power Supply Front Panel Referring to Figure 9: 1. SET UP/NORMAL SWITCH: In the SET UP position, this switch enables sync test and adjustment. The red LED blinks when the switch is in the SET UP position.
  • Page 12: Video Input Module

    Video Input Module Note: VIMs are installed, configured, and labeled either in the factory or by a technician in the field. As directed by the keyboard, an AD2016AVIM (Figure 10) selects which one of up to 16 video inputs is used for display (primary switch). The video path is shown on Figure 11.
  • Page 13 Figure 12. Video path through VIM-2, VIM-3 and VIM 4 VIM-2 VIM-3 VIM-4 AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS INSTALLATION GUIDE Configuring a VIM Back Plane Circuit Board Set the VIM to identify the inputs and outputs it is to respond to.
  • Page 14 3105-3120 49-64 1073-1088 2097-2112 3121-3136 65-80 1089-1104 2113-2128 3137-3152 81-96 1105-1120 2129-2144 3153-3168 97-112 1121-1136 2145-2160 3169-3184 113-128 1137-1152 2161-2176 3185-3200 129-144 1153-1168 2177-2192 145-160 1169-1184 2193-2208 161-176 1185-1200 2209-2224 177-192 1201-1216 2225-2240 193-208 1217-1232 2241-2256 209-224 1233-1248 2257-2272 225-240...
  • Page 15 Table 5. VIM video input identification (0 = OFF, 1 = ON, X = Don't Care), continued Input Input Input 481-496 1505-1520 2529-2544 497-512 1521-1536 2545-2560 513-528 1537-1552 2561-2576 529-544 1553-1568 2577-2592 545-560 1569-1584 2593-2608 561-576 1585-1600 2609-2624 577-592 1601-1616 2625-2640 593-608 1617-1632...
  • Page 16: Data Buffer Module

    Data Buffer Module The AD2010DB-01 data buffer (Figure 14) is used when video must be amplified and sent externally to a VOM(s) in another bay (see Figure 15). The data buffer: • Amplifies video for up to 16 video inputs (but does not provide a text overlay).
  • Page 17 Figure 15. Example: Bay examples showing data buffer use 1 Bay Example: Cameras 1 to 192 are internally VOMs routed to VOMs (no cables required) Video Out 2 Bays Example: VIMs VOMs Video Out Cameras in this bay are internally routed to VOM outputs AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS...
  • Page 18 1024 Pass all information packets for cameras 1-3200 (Default) CAUTION: Turn the filter on only when the bay in which it resides is dedicated to VIMs! Turning the filter on reduces AD data line switch packets.
  • Page 19 33-48 97-112 2817-3072 33-48 97-112 2049-2304 49-64 113-128 2305-2560 49-64 113-128 2561-2816 49-64 113-128 2817-3072 49-64 113-128 3073-3200 1-16 65-80 3073-3200 17-32 81-96 3073-3200 33-48 97-112 3073-3200 49-64 113-128 AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS INSTALLATION GUIDE ADDL3 ADDL4 Output...
  • Page 20: Video Output Module

    Video Output Module The AD2024BVOM: • As directed by the keyboard, acts as a secondary switch by selecting which of its four video outputs (A, B, C, or D) connects to the video input selected by the VIM of a camera group.
  • Page 21 BVOM rear panels: A BVOM can have one of three rear panels (Figure 19): • AD2024BVOM-1: - Supports up to three external camera groups, one internal camera group, and up to four video outputs. - The bottom four BNCs are the video outputs for the four camera groups.
  • Page 22 Configuring a BVOM CAUTION: A BVOM circuit board can plug into any unused slot that has a rear BVOM BNC panel. However, to install the system efficiently and to facilitate troubleshooting, ALWAYS install BVOMs in series beginning at the left-most slot as viewed from the rear of the bay.
  • Page 23 Cameras Group(s) 1 – 256 None 257 – 512 513 – 768 769 – 1024 METHOD 2: BVOM video input identification for up to 3200 cameras (0 = OFF, 1 = ON) External Internal Internal Camera Camera Group Cameras Group(s) 1 –...
  • Page 24: Connecting Cables

    VOM-4s. The loop panel is typically used when camera numbers exceed 1024. For instructions on how to use the ADULP with MegaPower 3200 switching systems, see AD Universal Loop Panel Installation Instructions 8000-0900-01. 4. Connect video output devices, such as monitors or video recorders, to one of the four outputs of each VOM.
  • Page 25: Powering Up The Bay

    Powering Up the Bay 1. Unscrew the two thumbscrews at the top corners of the bay’s front panel. 2. Slowly pull the top of the front panel towards the front and lift it up to remove it. 3. Verify that power to the bay is OFF (the On/Off switch on the front panel should not be lit).
  • Page 26: Adjusting Title Criteria

    EXT CAM: If composite video controls the vertical switching point, switch the Sync Reference Selection switch to EXT CAM (external camera). The composite sync signal should not exceed 1.1Vp-p. 1. Connect the composite sync to the EXT SYNC IN BNC located on the power supply rear panel. 2.
  • Page 27: Specifications

    Specifications Operational Bandwidth... 17MHz Frequency response ... ±0.5dB to 12MHz S/N ratio... 65dB (Vp-p vs. Vrms noise) Crosstalk Adjacent channels ...–55dB (at 3.58MHz) Input-to-input ...–70dB (at 3.58MHz) Differential delay ... ±1.0˚ Differential phase... 1.5˚ or better Differential gain... 1.0% or better Tilt...
  • Page 28: Or (561)

    AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS INSTALLATION GUIDE Other Declarations Thank you for using American Dynamics products. We support our products through an extensive and worldwide network of dealers. The dealer, through whom you originally purchased this product, is your point of contact if you have a need for service or support.
  • Page 29: Appendix A: Ad2010Dbvl Video Loss Detector Data Buffer Module

    Maximum cable length between an RS-232 device and the terminal box is 15m (50ft), using 18AWG shielded, computer- grade cable. • All American Dynamics equipment is configured as RS-232 DTE (Data Terminal Equipment) devices. For DTE-to-DTE connections, the MegaPower CPU RS-232 port: - XMIT pin connects to RCD (pin 4) of the terminal box going to the AD2010DBVL.
  • Page 30 Figure 25. Sample AD2010DBVL rear panel AD2010DBVL-01 AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS INSTALLATION GUIDE AD2010DBVL Configuration Procedure The data buffer module with video loss detection has four switches: slide switch S1, and 8-position switches S2, S3, and S4 (Figure 26). 1.
  • Page 31 Pass all information packets for cameras less than or equal to 1024 Pass all information packets for cameras 1–3200 (Default) Alarm during video or sync loss Alarm during loss, plus 10 seconds Alarm at loss for 10 seconds Alarm at loss for 20 seconds...
  • Page 32: Appendix B: Ad2024Mdt Master Date/Time Module

    APPENDIX B: AD2024MDT Master Date/Time Module The AD2024MDT has four looping video inputs and four separate video outputs with system time/date information. This module provides: • Looping connection for the video input signals • Insertion of time/date text on the video output connections.
  • Page 33: Appendix C: Optional Equipment

    Four-Channel Character Generator (AD1024CG) Displays same title, time/date information as an AD2024VOM or can operate as a standalone unit. Interfaces with MegaPower 3200 System via an AD data line. Recorder Control Devices The series of recorder control devices allows for remote control of video recorders via the AD2088 full system keyboard.
  • Page 34: Appendix D: System Configuration Examples

    APPENDIX D: System Configuration Examples Figure 28. 208 bays: 3072 inputs x 256 outputs (maximum VOM-4 system)... 33 Figure 29. 52 bays: 768 inputs x 256 outputs (maximum VOM-1 system)... 34 Figure 30. 7 bays: 832 inputs x 32 outputs (maximum Level 2 condensed system) ... 35 Figure 31.
  • Page 35 161 - 192 Level 13 & 14 193 - 224 Level 15 & 16 225 - 256 For cameras 1025–3200, ADULP Universal Looping Panels required for Data Buffer to VOM connections. AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS INSTALLATION GUIDE Camera Inputs...
  • Page 36 Figure 29. 52 bays: 768 inputs x 256 outputs (maximum VOM-1 system: 3 camera groups x 16 monitor levels) Product Code: ADMPR768-256N Components used: • 52 Bays (Configuration using 52 dedicated bays controlled by 4 AD Data Lines) • 48 VIM-2s •...
  • Page 37 Figure 30. 7 bays: 832 inputs x 32 outputs (maximum Level 2 condensed system: 4 camera groups x 2 monitor levels) Product Code: ADMPR832-32N Components used: • 7 Bays (Configuration using 1 condensed bay and 6 dedicated bays controlled by 1 AD Data Line) •...
  • Page 38 Figure 31. 8 bays: 64 inputs x 256 outputs (maximum condensed system with 64 or less inputs: 1 camera group x 16 monitor levels) Product Code: ADMPR64-256N Components used: • 8 Bays (Configuration using 8 condensed bays controlled by 2 AD Data Lines) •...
  • Page 39 Figure 32. 1 bay: 256 inputs x 16 outputs (1 camera Group x 1 monitor level)—with no titles AD Data Line 1 AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 37 of 64 INSTALLATION GUIDE...
  • Page 40 Figure 33. 1 bay: 192 inputs x 16 outputs (1 camera group x 1 monitor level)—with titles AD Data Line 1 AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 38 of 64 INSTALLATION GUIDE...
  • Page 41 Figure 34. 2 bays: 448 inputs x 16 outputs (2 camera groups x 1 monitor level) AD Data Line 1 AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 39 of 64 INSTALLATION GUIDE...
  • Page 42 Figure 35. 3 bays: 704 inputs x 16 outputs (3 camera groups x 1 monitor level) Data Line to Bays AD Data Line 1 Data Line to Bays AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 40 of 64 INSTALLATION GUIDE...
  • Page 43 Figure 36. 4 bays: 960 inputs x 16 outputs (4 camera groups x 1 monitor level) Data Line to Bays Data Line to Bays AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 41 of 64 INSTALLATION GUIDE...
  • Page 44 Figure 37. 1 bay: 64 inputs x 32 outputs (1 camera group x 2 monitor levels) AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 42 of 64 INSTALLATION GUIDE...
  • Page 45 Figure 38. 2 bays: 192 inputs x 32 outputs (1 camera group x 2 monitor levels) AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 43 of 64 INSTALLATION GUIDE...
  • Page 46 Figure 39. 3 bays: 320 inputs x 32 outputs (2 camera groups x 2 monitor levels) AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 44 of 64 INSTALLATION GUIDE...
  • Page 47 Figure 40. 4 bays: 448 inputs x 32 outputs (2 camera groups x 2 monitor levels) AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 45 of 64 INSTALLATION GUIDE...
  • Page 48 Figure 41 (1 of 2). 6 bays: 704 inputs x 32 outputs (3 camera groups x 2 monitor levels) AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 46 of 64 INSTALLATION GUIDE...
  • Page 49 Figure 41 (2 of 2) AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 47 of 64 INSTALLATION GUIDE...
  • Page 50 Figure 42 (1 of 2). 8 bays: 960 inputs x 32 outputs (4 camera groups x 2 monitor levels) AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 48 of 64 INSTALLATION GUIDE...
  • Page 51 Figure 42 (2 of 2) AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 49 of 64 INSTALLATION GUIDE...
  • Page 52 Figure 43. 3 bays: 192 inputs x 48 outputs (1 camera group x 4 monitor levels) AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 50 of 64 INSTALLATION GUIDE...
  • Page 53 Figure 44. 4 bays: 256 inputs x 48 outputs (1 camera group x 4 monitor levels) AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 51 of 64 INSTALLATION GUIDE...
  • Page 54 Figure 45. 6 bays: 448 inputs x 48 outputs (1 camera group x 4 monitor levels) AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 52 of 64 INSTALLATION GUIDE...
  • Page 55 Figure 46 (1 of 2). 9 bays: 704 inputs x 48 outputs (3 camera groups x 4 monitor levels) AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 53 of 64 INSTALLATION GUIDE...
  • Page 56 Figure 46 (2 of 2) AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 54 of 64 INSTALLATION GUIDE...
  • Page 57 Figure 47 (1 of 2). 10 bays: 768 inputs x 48 outputs (3 camera groups x 4 monitor levels) AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 55 of 64 INSTALLATION GUIDE...
  • Page 58 Figure 47 (2 of 2) AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 56 of 64 INSTALLATION GUIDE...
  • Page 59 Figure 48. 4 bays: 64 inputs x 128 outputs (1 camera group x 8 monitor levels) AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS INSTALLATION GUIDE 57 of 64 AD Data Line 1 75-ohm Terminator AD Data Line 2 75-ohm Terminator 8200-0421-08, REV. B...
  • Page 60 Figure 49. 1 bay: 256 inputs x 15 outputs (1 camera group x 1 monitor level)—with video loss detection AD Data Line 1 AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS INSTALLATION GUIDE MegaPower CPU 58 of 64 Video loss detection alarm output from AD2010DBVL module...
  • Page 61 Figure 50. 1 bay: 256 inputs x 15 outputs (1 camera group x 1 monitor level)—with video loss detection and alarm outputs Alarm Contact Alarm Ground AD2096 Alarm Interface MegaPower CPU AD Data Line 1 Video loss detection alarm output from AD2010DBVL module AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS...
  • Page 62 Figure 51. AD2010DBVL to AD2081 Port Expander to MegaPower CPU Up to four AD2010DBVL modules can connect to one port expander using the following port assignments: 3073– 3200 2817– 2561– CG13 3072 2816 Camera CG12 CG11 Groups AD2081 MPCPU Detailed Example:...
  • Page 63 Figure 52. 2 bays: 448 inputs x 15 outputs (2 camera groups x 1 monitor level)—with video loss detection and AD2081 port expander AD2081 Port Expander AD Data Line 1 MegaPower CPU AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 61 of 64 INSTALLATION GUIDE...
  • Page 64 Figure 53. Video connections—data buffer outputs 1–4 to VOMs Input Bay Input Bay Input Bay Output 1-256 257-512 513-768 AD2010DB-1x AD2010DB-2x AD2010DB-3x AD2024BVOM-1 AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 62 of 64 INSTALLATION GUIDE...
  • Page 65 Figure 54. Video connections—data buffer outputs 125–128 to VOMs Input Bay Input Bay Input Bay Output 1-256 257-512 513-768 125-128 AD2010DB-1x AD2010DB-2x AD2010DB-3x AD2024BVOM-1 AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 63 of 64 INSTALLATION GUIDE...
  • Page 66 Notes: AD2010N/P AND AD2020N/P MATRIX SWITCHING BAYS 8200-0421-08, REV. B 64 of 64 INSTALLATION GUIDE...
  • Page 68 Please visit our website for more information www.americandynamics.net © 2008 Sensormatic Electronics Corporation Product specifications subject to change without notice. Certain product names mentioned herein may be trade names 8200-0421-08 B and/or registered trademarks of Sensormatic or other companies.

This manual is also suitable for:

Ad2010nAd2010pAd2020nAd2020p

Table of Contents