Pepperl+Fuchs K23-SSI/Rx/IU-C Manual page 35

Signal converter
Table of Contents

Advertisement

SSI OFFSET
In the case of a "RESET/SET VALUE" command (via control input or PC user
interface), the as yet unscaled position value currently being recorded (after bit
suppression and any rotary encoder zero point shift) is transferred to the "SSI
OFFSET" parameter and the measurement result is reset to zero. From the new
zero point, it is now possible to move in the positive and negative directions,
depending on the direction of rotation.
(Display zero point shift)
Value
Function
0
Smallest value
...
999999999
Largest value
ROUND LOOP VALUE
Defines the number of rotary encoder steps if a concentricity function is desired.
Value
Function
0
No concentricity
...
99999999
Number of steps for the concentricity function
SAMPLING TIME (S)
Determines the read-in cycle for the SSI signal in the managing operation
Value
Function
0.001
Minimum measuring time in seconds
0.010
Default value
9.999
Maximum measuring time in seconds
| O
S
PERATING
OFTWARE
OS6.0 / OS10.0