Pepperl+Fuchs K23-SSI/Rx/IU-C Manual page 27

Signal converter
Table of Contents

Advertisement

STANDSTILL TIME 1 (S)
This parameter defines the downtime. If
channel A, a downtime is signaled after xx.xx seconds and the startup
override is reactivated. Downtime monitoring can be set in the
PRESELECTION menu.
Value
Function
0.01
Shortest delay time in seconds
...
99.99
Longest delay time in seconds
AVERAGE FILTER 1 (average determination)
Switchable average determination or filter function at unstable frequencies at
input A for smoothing the analog signal. If the filter is set to 5 ... 16, the device
uses an exponential function. The time constant T (63 %) corresponds to the
number of sampling cycles.
For example, SAMPLING TIME = 0.1 s and AVERAGE FILTER = exponential
filter,
T (63 %) = 2 x sampling time.
This means that after 0.2 s, 63 % of the jump height is reached.
Value
Function
0
No average determination
(quick response to any change)
1
Flowing average determination with two cycles
2
Flowing average determination with four cycles
3
Flowing average determination with eight cycles
4
Flowing average determination with 16 cycles
5
Exponential filter, T (63 %) = 2x SAMPLING TIME
6
Exponential filter, T (63 %) = 4x SAMPLING TIME
7
Exponential filter, T (63 %) = 8x SAMPLING TIME
8
Exponential filter, T (63 %) = 16x SAMPLING TIME
9
Exponential filter, T (63 %) = 32x SAMPLING TIME
10
Exponential filter, T (63 %) = 64x SAMPLING TIME
11
Exponential filter, T (63 %) = 128x SAMPLING TIME
12
Exponential filter, T (63 %) = 256x SAMPLING TIME
13
Exponential filter, T (63 %) = 512x SAMPLING TIME
14
Exponential filter, T (63 %) = 1024x SAMPLING TIME
15
Exponential filter, T (63 %) = 2048x SAMPLING TIME
| O
S
PERATING
OFTWARE
is detected at
frequency = 0 Hz
OS6.0 / OS10.0
27