ENCODER PROPERTIES
This parameter defines the characteristics of the incremental input.
Value
Designation
0
RS422
HTL
1
DIFFERENTIAL
2
HTL PNP
3
HTL NPN
4
TTL PNP
ENCODER DIRECTION
This parameter reverses the direction of counting and/or travel.
Value
Designation
0
FORWARD
1
REVERSE
FACTOR (multiplication factor)
This parameter defines the factor by which the measurement result is
multiplied.
Value
Function
-99999999
Smallest value
Default value
1
99999999
Largest value
DIVIDER (division factor)
This parameter defines the divisor by which the measurement result is divided.
Value
Function
-99999999
Smallest value
Default value
1
99999999
Largest value
| O
PERATING
Function
RS422 standard
HTL differential
PNP (switching to +)
NPN (switching to -)
TTL PNP (switching to +)
Function
Forward
Backward
S
OS6.0 / OS10.0
OFTWARE