Installing Your Stove

Venting Your Stove

CAUTION!
Take appropriate precautions to locate utilities within the wall and avoid contact.
Mark and cut wall for venting penetration on exterior wall (if needed).
1
2
Install wall thimble (sold separately) per manufacturer requirements.
Install venting. (For additional installation options visit pelprostoves.com)
3
Use silicone to create an effective vapor barrier at the location where the chimney or other compo-
4
nent penetrates to the exterior of the structure.
Vertical - Interior, Preferred Installation
Rain Cap
Flashing
12 in. (305mm) Minimum
Firestop
Ceiling Support
6 in.
Follow pipe manufacturer
(152mm)
listed clearance
Min.
Clean-out T
Non-combustible Hearth Pad
NOTE: In Canada when using a factory-built chimney it must be safety listed, Type UL103 HT (2100 o F) CLASS "A" or
conforming to CAN/ULC-S629M, STANDARD FOR 650 o C FACTORY-BUILT CHIMNEYS.
Pro Tips
See venting manufacturer's required clearances to combustibles
For horizontal installations, the minimum clearance from exterior to termination cap is 6"—you
may want to increase to 18" clearance to minimize soot blow back on home exterior.
Install vent at clearances specified by the manufacturer
WARNING!
Do not terminate venting in any enclosed or semi-enclosed area
such as: a carport, garage, attic, crawl space, under a sun deck
or porch, narrow walkway or closely fenced area, or any location
that can build up a concentration of fumes such as a stairwell,
covered breezeway, etc.
10
PelPro Cast Pellet Stove • 7093-600J • 04/21
Exterior - Optional Installations
Termination
Wall Thimble
Cap
6 in.
(152 mm)
Minimum
Wall Thimble
6 in. (152 mm)
Minimum
Horizontal
Termination Cap
6 in.
(152 mm)
Non-combustible
Clean Out T
Minimum
Hearth Pad
CAUTION!
Ensure that your Stove venting terminates above
your Stove. The following may occur:
• Your Stove Stove will not draft properly
• Smoke may seep in your house
• Excessive sooting
pelprostoves.com
Installing Your Stove
Venting Your Stove
The maximum horizontal venting allowed with no vertical venting
attached is 48 inches including one 90° elbow or two 45° elbows.
Addition of any horizontal venting beyond 48 inches requires a
minimum 60 inches of additional vertical vent. Horizontal sections
of vent pipe should have a 1/4 inch rise per foot. We recommend
using the shortest venting and fewest elbows possible when venting
horizontal.
We recommend the use of 4 inch vent with any installation requiring
more than two 90° elbows, or more than 15 feet of venting.
45° elbow is equivalent to 1 foot of straight pipe
90° elbow is equivalent to 3 feet of straight pipe
ONE 90° ELBOW
Total
Minimum
Vent
TWO 90° ELBOWS
Horizontal
Vertical
Diameter
Total
4
0
3
Horizontal
5
5
3
2
6
6
3
3
7
7
3
4
8
8
4
5
9
9
4
6
10
10
4
7
11
11
4
8
12
12
4
9
13
13
4
10
14
14
4
11
15
15
4
12
16
16
4
13
17
17
4
14
18
18
4
15
19
19
4
Minimum Vertical Vent for One Elbow
Minimum Vertical Vent for One Elbow
Minimum Vertical Vent for Two Elbows
20
20
15
15
10
10
5
5
0
0
0
5
10
15
20
0
Horizontal Run (FT)
Horizontal Run, (ft)
Length of Horizontal Sections (FT)
pelprostoves.com
PelPro Cast Pellet Stove • 7093-600J • 04/21
WARNING!
Fire Risk.
Only LISTED
venting components
may be used
NO OTHER vent components may
be used. Substitute or damaged
vent components may impair safe
operation.
Notice:
These are guidelines for successful
venting of your pellet Stove. The more
vertical rise you can obtain in your sys-
tem, the better it will perform. Horizontal
vent runs can accumulate ash and will
need to be cleaned more often. Try to
keep them as short as possible.
Minimum
Vent
Vertical
Diameter
5
3
THREE 90° ELBOWS
6
3
7
3
Total
Minimum
Vent
8
3
Horizontal
Vertical
Diameter
9
3
2
11
4
10
4
3
12
4
11
4
4
13
4
12
4
5
14
4
13
4
6
15
4
14
4
7
16
4
15
4
8
17
4
16
4
9
18
4
17
4
10
19
4
18
4
11
20
4
Minimum Vertical Vent for Three Elbows
25
20
15
10
5
0
5
10
15
0
2
4
6
8
Length of Horizontal Sections (FT)
10
12
11

Hide quick links: