Installing Your Stove

Vent Termination Clearances

B
D
A
Clearances
A
12"
Clearance above grade, veranda porch, deck or balcony (Including vegetation and mulch)
12" with outside air kit
Clearance beside or below any windows or doors that open
48" no outside air kit
B
12"*
Clearance above any window or door that opens
Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet from
C
18"
the center line of the terminal
D
12"
Clearance to an outside corner wall
12" with outside air kit
F
Clearance to a non-mechanical air supply inlet to the building or a combustion air inlet to any other Stove
48" no outside air kit
G
36"
Clearance to a mechanical air supply inlet
H
84"**
Clearance above a paved sidewalk or paved driveway located on public property
I
12"**
Clearance under a veranda, porch, deck or balcony
J
12"
Clearance above the roof
K
24"
Clearance from an adjacent wall including neighboring buildings
36" within a height of 15
Clearance to each side of center line extended above natural gas or propane meter / regulator assembly
L
feet above the meter /
or mechanical vent
regulator assembly
*Recommended to prevent condensation on windows and thermal breakage. **This is a recommended distance. For additional requirements check local codes.
Notice:
Do NOT terminate vent:
In any location that will allow flue gases or soot from
entering or staining the building
In any location which could create a nuisance or hazard
In any enclosed or semi-enclosed area such as a
carport, garage, attic, crawl space, under a sun deck or
porch or narrow walkway
Closely fenced area, or any location that can build up
a concentration of fumes such as a stairwell, covered
breezeway, etc.
8
PelPro Cast Pellet Stove • 7093-600J • 04/21
C
K
J
I
B
F
G
H
L
Notice:
Do NOT terminate below an air inlet.
It is recommended that at least 60" (1.52m) of vertical
pipe be installed when Stove is vented directly through
a wall—this will create a natural draft, which will help
prevent the possibility of smoke or odor venting into the
home during a power outage
It will also keep exhaust from causing a nuisance or
hazard by exposing people or shrubs to high tempera-
tures
The safest and preferred venting method is to extend
the vent vertically through the roof or above the roof
pelprostoves.com
Installing Your Stove

Placing Your Stove

Stove must be installed on a non-combustible floor. If need-
1
ed, place floor protection (such as a hearth pad) beneath the
Stove. Move Stove from pallet onto your non-combustible sur-
face. Do not operate the Stove while it sits on the pallet.
Notice: Be careful to protect the bottom of the Stove and floor sur-
faces when moving the Stove. Bottom edges of Stove are sharp
and can scratch surfaces.
Notice: Clearances may only be reduced by means approved by
the regulatory authority having jurisdiction.
2
Hearth pad minimum requirements:
USA Hearth Pad Requirements
Inches
A
Sides
2
B
Back
2
C
Front
6
Canada Hearth Pad Requirements
Inches
A
Sides
8
B
Back
2
C
Front
6
Non-combustible floor protection extending beneath the flue pipe is required
with horizontal venting or under the top vent adapter with vertical installation.
*Non-combustible floor protection must extend 2 inches (51mm) beneath the
flue pipe when installed horizontal venting or under the top vent adapter with
vertical installation. CANADA REQUIRED, USA RECOMMENDED.
Confirm required clearances to combustibles:
3
Vertical Installations (Interior Flue)
Straight back against wall
Inches
D
Back wall to pellet pipe
3
E
Side wall to Stove
13
Corner Installation
Straight back against wall
Inches
F
Walls to Stove
3
Horizontal Installations
Straight back against wall
Inches
G
Back wall to Stove
2
E
Side wall to Stove
13
H
Clearance to top of Stove
7
J
Clearance to front of Stove
48
pelprostoves.com
PelPro Cast Pellet Stove • 7093-600J • 04/21
1
2
B*
mm
A
A
51
51
C
152
mm
203
3
51
D
G
152
E
J
F
mm
F
76
330
J
mm
H
76
J
mm
51
330
178
1219