Summary of Contents for HYDAC ELECTRONIC ETS 1700

  • Page 1 Elektronischer Temperaturschalter Electronic Temperature Switch Thermocontacteur électronique ETS 1700...
  • Page 2 Diese Bedienungsanleitung haben wir nach bestem Wissen und gewissen erstellt. Es ist dennoch nicht auszuschließen, dass trotz größter sorgfalt sich Funktionen des Ets 1700 Fehler eingeschlichen haben könnten. Haben sie bitte deshalb Verständnis dafür, dass wir, soweit sich nachstehend nichts anderes ergibt, unsere Montage gewährleistung und Haftung - gleich aus welchen Rechtsgründen - für die...
  • Page 3 Geräteeinbaustecker (im tfP 104) Montage 4-pol. binder, serie 714 die Montage des Ets 1700 erfolgt über die 4 befestigungsbohrungen in der Pin 1 = + Versorgung Geräteeinbau- Gehäuserückwand. in kritischen anwendungsfällen (z. b. starke Vibrationen Pin 2 = + signal stecker, 4-pol.
  • Page 4 6.1 rElaisausGänGE temperatur- anzeige der Ets 1700 besitzt 4 relaisausgänge. zu jedem relais können ein schaltpunkt und ein rückschaltpunkt bzw. eine hysterese eingestellt werden. das jeweilige relais zieht an, wenn der eingestellte schaltpunkt erreicht wurde, und fällt ab, wenn der rückschaltpunkt unterschritten wurde.
  • Page 5 Maximalwert ist der höchste temperaturwert, der seit Einschalten des zur anpassung an die jeweilige applikation kann das Verhalten des Ets 1700 Gerätes oder seit dem letzten rücksetzvorgang aufgetreten ist. über mehrere Grundeinstellungen verändert werden. diese sind zu einem Menü...
  • Page 6 (nur bei Einstellung "ranG" = "frEE") 0.000 Rückschaltmodus (switch Mode) r.s.P./ hyst. anzahl der nachkommastellen, die der "r.s.P": der Ets 1700 arbeitet mit ein- hyst. Ets 1700 anzeigt. stellbaren rückschaltpunkten. unterer anzeigebereich (Range low) -995 .. "hyst": der Ets 1700 arbeitet mit ein- (nur bei Einstellung "ranG"...
  • Page 7 Programmierfreigaben Einstellung anzeige Einstell- Vorein- das Gerät verfügt über 2 Programmierfreigaben die beide erteilt sein müssen bereich stellung um Einstellungen zu ändern. die software-Programmierfreigabe kann analogausgang (Output) MaMP/ Volt während des betriebes gesetzt bzw. aufgehoben werden. sie bietet schutz "MaMP": der analogausgang liefert Volt vor unbeabsichtigten änderungen.
  • Page 8 Werk zurück. – – – – bei den abgespeicherten kalibrierdaten wurde ein fehler erkannt. sensoranschluß Mögliche ursachen sind starke elektromagnetische störungen oder ein bauteildefekt. abhilfe: kontrollieren sie die spannungsversorgung zum Ets 1700 sensoranschluß bild 1 bild 2...
  • Page 9 übersteuerungsschutz, lastkurzschlussfestigkeit sind vorhanden. Eingangskenngrößen * der Mediumstemperaturbereich des angeschlossenen Messbereich 0 .. +100 °c (+32 .. 212 °f)* temperatursensors kann den anzeigebereich des Ets 1700 ausgangsgrößen einschränken. Genauigkeit (anzeige, analogausgang) ≤ ± 1,0 °c (≤ ± 2,0°f) Fs (Full scale) = bezogen auf den vollen Messbereich reproduzierbarkeit ≤...
  • Page 10 13. Bestellangaben 15. geräteabmessungen Ets 1 7 0 X - 100 - 000 sensorart = für Pt 100 sensoren (sensor tfP 100 muß separat bestellt werden, siehe unten) anzeige kabelverschraubung PG11 = 4-stellig °c = 4-stellig °f senkung din74-kM5 Meßbereich 100 = 0 ..
  • Page 11: Table Of Contents

    Contents Functions of the Ets 1700 Mounting Pin connections 3.1. sEnsor connEction 3.2. rElay outPuts, analoGuE outPut, suPPly VoltaGE Operating keys on the membrane keypad Digital display Output functions 6.1. rElay outPuts 6.2. analoGuE outPut 6.3. sEttinG thE sWitchinG Points and...
  • Page 12: Functions Of The Ets 1700

    (on the tfP 104) Mounting 4-polebinderconnector , series 714 the Ets 1700 is mounted via the 4 mounting holes in the rear panel of the 4-pole Pin 1 = + supply housing. in critical applications (e. g. strong vibrations or knocks), the...
  • Page 13: Setting The Switching Points And Switch-Back Points / Hystereses

    (only possible if the switch-back mode is set to "hysteresis".) Output function 6.1 rElay outPuts the Ets 1700 has 4 relay outputs. one switching point and one switch-back temperature display point and/or one hysteresis can be set for each relay. the appropriate relay pulls in when the pre-set switching point is reached and drops back when the temperature falls below the switch-back point.
  • Page 14: Maximum Value

    7.2. rE-sEttinG thE Max ValuE to close the basic setting menu: call up the menu point EnD, set to YEs, the Ets 1700 returns to the normal display mode after 2s. temperature display Press On and OFF keys of switching point 1 simultaneously, EnD is displayed, the Ets 1700 returns to normal display mode after 2s.
  • Page 15: Summary Of The Basic Settings

    (switch Mode) r.s.P./ hyst. upper display range (Range High) -995 .. measur- "r.s.P": the Ets 1700 operates with hyst. (only when set to "ranG"="frEE") 9995 ing range adjustable switch-back points. Upper display range limit final value "hyst": the Ets 1700 operates with...
  • Page 16: Programming Enable

    Programming enable setting display setting Pre- the unit has 2 types of programming enable which must both be set to "on" to range setting change the settings. the software programming enable can be set or removed analogue output (Output) MaMP/ Volt during operation.
  • Page 17: Altering The Hardware Programming Enable

    – – – – an error has been detected in the stored calibration data. Possible causes are strong electromagnetic interference or a component fault. sensor connection action: check the supply voltage to the Ets 1700 sensor connection figure 1 figure 2...
  • Page 18: Technical Specifications

    * The fluid temperature range of the connected temperature sensor can Measuring range 0 .. +100 °c (+32 .. 212 °f)* restrict the display range of the Ets 1700. Output data Fs (Full scale) = relative to the complete measuring range accuracy (display, analogue output) ≤...
  • Page 19: Model Code

    13. Model code 15. Dimensions Ets 1 7 0 X - 100 - 000 type of sensor = for Pt 100 sensors (sensor tfP 100 must be ordered separately, see below) Display = 4-digit °c cable gland PG11 = 4-digit °f countersunk to din74-kM5 Measuring range 100 = 0 ..
  • Page 20 9.1. Modification dEs droits dE ProGraMMation 9.2. Modification MatEriEllE dE la ProGraMMation Possibilitées de montage de l'Ets 1700 Messages d'erreur Données techniques Données de commande accessoires 14.1. accEssoirEs liVrEs En standard 14.2.
  • Page 21: Fonctions De L'ets 1700

    Montage Pin 1 = + alimentation (côte sonde de le montage de l'Ets 1700 se fait par quatre percages présents sur le boîtier. Pin 2 = + signal température) le raccordement de la sonde se fait par l’intermédiaire d’un câble électrique...
  • Page 22: Affichage Digital

    Affichage digital 6.3 réGlaGEs dEs Points d'EnclEnchEMEnt Et dE réEnclEnchEMEnt après l'avoir mis sous tension, l'Ets 1700 indique brièvement "Ets"puis  sélectionner la touche correspondante donne la valeur actuelle de température.  Le point d'enclenchement / réenclenchement est affiché : "s.P.1"...
  • Page 23: Valeur Maximale

    "EnD" puis "YEs" : l'Ets1700 retourne alors dans le mode affichage normal Valeur appuyer sur les touches "On" et "OFF" du seuil 1, "EnD" s'affiche : température l'ETS 1700 retourne alors dans le mode d'affichage standard remarques : appuyer indication la valeur maximale ...
  • Page 24: Aperçu Des Reglages De Base

    Valeur Mode commutation (switch Mode) r.s.P./ hyst. (uniquement avec "RANG"="FREE") 9995 de fin "r.s.P": l’Ets 1700 travaille avec hyst. Entrée de la fin d'échelle d'affichage de plage un point de déclenchement. "hyst": l’Ets 1700 travaille avec une hystérésis préréglée (voir aussi § 6.1. "sorties sur relais")
  • Page 25: Autorisation De Programmation

    autorisation de programmation Réglages Affichage Plage de Pré- 2 autorisations de programmation sont nécessaires pour pouvoir modifier réglage réglage le paramétrage des différentes fonctions. l'autorisation logicielle peut être sortie analogique (Output) MaMP/ Volt modifiée à tout moment pendant l'utilisation de l'appareil. Le verrouillage "MaMP": le signal en sortie est matériel (interrupteur) enlève toute possibilité...
  • Page 26: Programmation

    électromagnétique ou d'un composant défectueux. fig. 1 fig. 2 10. Possibilités de montage de l'Ets 1700 Remède: après validation du défaut, l'appareil va fonctionner avec une précision  couper l’alimentation. réduite. Vérifier tous les paramètres importants (points de déclenchement, ...
  • Page 27: Données Techniques

    0 .. +100 °c (+32 .. 212 °f)* * La plage de température du fluide du capteur de température signaux de sortie connecté peut diminuer l'affichage de l'ETS 1700. Précision (affichage, sortie analogique) ≤ 1,0 °C (≤ ± 2,0 °F) PE (pleine échelle) = par rapport à...
  • Page 28: Données De Commande

    13. Donées de commande 15. Dimensions Ets 1 7 0 X - 100 - 000 type de capteur = capteur Pt 100 (capteut tfP à commander séparément, voir ci-dessous) Affichage Presse étoupe PG11 = 4 digits en °c = 4 digits en °f lamage din74-kM5 Plage de mesure 100 = 0 ..
  • Page 29 Fax: (0060) 3 -55670252 Tel.: 0 68 97 / 509-01 E-mail: common@hydac.com.my Fax: 0 68 97 / 509-1422 HYDAC-Büro Süd hauptstraße 27 HYDac Electronic gMBH Dieselstraße 30 66128 saarbrücken D-71546 Aspach Tel.: 0 71 91 / 34 51-0 Phone: Fax: 0 71 91 / 34 51-4033...

This manual is also suitable for:

Ets 17001-100-000Ets 17002-100-000