Accuracy (1)
Resolution
Measurement range
Maximum overpressure
(without degrading)
Measurement principle
Power supply
Input impedance
Insulation resistance (at 50Vdc)
Output signal Full Scale FSO
Zero signals adjustment (tollerance ± 0.5% FSO)
Output impedance
Response time (10...90% FSO)
Output noise (RMS 10-400Hz)
Calibration signal
Output short circuit ingress and reverse polarity protection
Voltage spike protection
Compensed temperature range housing
Operating temperature range housing
Storage temperature range housing
Maximum diaphragm temperature
Zero signal variation due to process temperature variation in range
(20-350°C)
Span signal variation due to process temperature variation in range
(20-350°C)
Std contact diaphragm with process
Thermocouple (Model I32)
Protection degree (with 6-pole female connector)
Electrical connection
FSO = Full scale output.
(1) BFSL method (Best Fit Straight Line): includes combined effects of Non-Linearity, Hysteresis and Repeatability.
Sensors are manufactured in compliance with:
- EMC compatibility directive
- RoHS directive
Electrical installation requirements and Conformity certificate are available on our web site: www.gefran.com
80175G_MAN_I3-IE-IN-IX_I7_11-2018_ENG
6b - I3 Series - Technical data
H <±0.25%FSO
M <±0.5%FSO
16 bit
0..100 to 0..1000bar
0..1500 to 0..15000psi
1,5 x FS 1,5 x FS
(maximum pressure 1200bar/17400psi)
Piezoresistive
8...12Vdc (10Vdc tipico)
350 Ohm ± 10%
>1000 MOhm
2,5mV/V (option 2)
3,33mV/V (option 3)
"Autozero" function
350 Ohm ± 10%
8ms (option 1ms)
< 0.025% FSO
80% FSO
YES
> 2KV burst test, to EN61000-4-4
0...+85°C
-30...+85°C
-40...+125°C
350°C
< ± 1,2%FSO
< ± 1%FSO
15-5 PH GTP+
STD: type "J" (isolated junction)
type "K" (on request)
IP65
Conn. 6-pin VPT07RA10-6PT
(PT02A-10-6P)
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ie seriesIn seriesIx seriesI7 series

Table of Contents