gefran I3 Series Instruction Manual page 27

Table of Contents

Advertisement

Command modes
The command modes must be used by the user only to make periodical recalibrations of the system in the
process, and are made through:
Pin CAL
Magnetic sensor
The event combinations give the following functions:
1.
Autozero
2.
Calibration (CAL)
3.
Reset autozero
1) A
utozero
Application mode
The Autozero function is activated by :
1) positioning the magnet near the Autozero label on the
shell of the sensor.
2) Short-circuiting the correct pins (e.g. pins E-F for the 6
pin connector) for the external Autozero version.
The magnet has to be maintained on the Autozero posi-
tion for a time within 2 to 5 seconds.
NOTES:
During the Autozero phase, the current output for the IE/IX transmitter series, can increase up to 7 mA.
That's a short variation only visible during the Autozero phase; it won't have any effects on the final signal.
Magnetic
2...5 seconds
pointer
Warning: the periodical zero ricalibration through the Autozero function must be done at stable tempe-
rature and no pressure in the extrusion chamber.
80175G_MAN_I3-IE-IN-IX_I7_11-2018_ENG
Limits
Result
± 40% F.S.
The Autozero effect will be visible after
waiting 2 seconds after the start of the
seconds.
The precision of the zero value will be
defined by the accuracy class of the
sensor.
1) Machine pressure = 0 bar and transducer
powered.
2) Put magnetic pointer on marked spot
(2...5 seconds).
3) Remove magnetic pointer.
4) Ready !
= marked spot
Remove
27