Response time
The response time at dangerous event is 8 ms.
The response time at a fail condition is 400 ms.
Environmental and operational limits
In order to maintain the device in the designated category it must work within the following limits (Tab.1):
Limit
Overpressure without degradation
Supply
Process fluid temperature
Operating electronic temperature
Storage temperature range
Dust protection
Water protection
Vibrational levels
EMC– Emissions
EMC – Immunity
Tab.1 - Environmental and operational limits
Suspension of the safety function
In IMPACT transducer it's not allowed any suspension or bypass of the safety function.
24
Voltage output
1,5 x FS
(maximum pressure
1200bar/17400psi)
15..30 Vdc
23..350 °C
-30..+85 °C
-40..+125 °C
IP 6X (EN 60529)
IP X5 (EN 60529)
EN 60068-2-6 (5g, 10..500 Hz)
EN 61326-1
EN 61326-2-3
EN 61326-1
EN 61326-2-3
Current output
1,5 x FS
(maximum pressure
1200bar/17400psi)
Load diagram
23..350 °C
-30..+85 °C
-40..+125 °C
IP 6X (EN 60529)
IP X5 (EN 60529)
EN 60068-2-6 (5g, 10..500 Hz)
EN 61326-1
EN 61326-2-3
EN 61326-1
EN 61326-2-3
80175G_MAN_I3-IE-IN-IX_I7_11-2018_ENG

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ie seriesIn seriesIx seriesI7 series

Table of Contents