The system must be used only in accordance with the required protection level.
The sensor must be protected against accidental knocks and used in accordance with the instrument's ambient characteristics and
performance levels.
The sensors must be powered with non-distributed networks and always at lengths of less than 30 mt.
In case of outdoor installations, follow the instructions in paragraph 5.
Transducers: Series MD / WD / KD / I / IJ
Outputs: CANopen DP404
Installation notes
- The transducer must be grounded (normally through the machine body or equipment it is installed on).
- Use a shielded cable only. The braiding must be connected to the case of the 5-pin connector. On instrument/PLC side, we advise you
connect the braiding without power supply (0V GND).
- To prevent interference, separate the power cables from the signal cables.
Machine
Press
Equipment
Ground
Series MD / WD / KD / I / IJ
Controller
Can Output
2

1. General Precautions

2. Transmitters with digital output

Standard installation (recommended)
MD / WD
transducer
Rod / Pressure intake
Cable connector
Electrical connections
CAN BUS DP404 digital output
5-pin
n.c.
Power supply +
Power supply -
Can H
Can L
Braiding connected to connector case
Shielded cable
1
2
3
4
5
M12 DIN EN 50044 5-pin connector
MAN_Electrical_Installation_for_Pressure_Probes_0709_ENG
PLC / Instrument
Braiding connected to 0V GND
of PLC / Instrument