Fig. 1.1
L
N
10 mm² max
ArtNo.130-0010 Electrical connections single-phase
230 V ac 50 Hz
Fig. 1.2
L1
N
L3
L2
6 mm² max
3N ac
230/400 V 50 Hz
national and local regulations and with the
local gas and electricity supply companies'
requirements.
All installations must be in accordance with the
relevant instructions in this booklet.
n
Note: The cooker must be connected to the
correct electrical supply as stated on the
6 mm² max
voltage label on the cooker, through a suitable
cooker control unit incorporating a double-pole
switch, having a contact separation of at least
3 mm in all poles.
n
Access to the mains terminal is gained by
removing the electrical terminal cover box on
the back panel. Connect the mains cable to the
6 mm² max
correct terminals for your electrical supply type
(Fig. 1.1 and Fig. 1.2). Check that the links are
10 mm² max
correctly fitted and that the terminal screws are
tight. Secure the mains cable using the cable
clamp.
Minimum temperature rating T105.
Read the instructions before installing or using
this appliance.
Gas connection safety
2
WARNING: THE APPLIANCE MUST
BE EARTHED.
The cooker MUST NOT be connected to
an ordinary domestic power point.
This cooker is a Class 2 Subclass 1
appliance.
This appliance can be converted for use on
another gas.
Before installation, make sure that the
cooker is suitable for your gas type and
supply voltage. See the data badge.
DO NOT use reconditioned or
unauthorised gas controls.
Disconnect from the electricity and gas
supply before servicing.
When servicing or replacing gas-carrying
components disconnect from the
gas supply before starting operation.