Rangemaster Professional+ FXP 90 Dual Fuel User's Manual & Installation Instructions page 5

Hide thumbs Also See for Professional+ FXP 90 Dual Fuel:
Table of Contents

Advertisement

Fig. 1.1
L
N
10 mm² max
ArtNo.130-0010 Electrical connections single-phase
230 V ac 50 Hz
Fig. 1.2
L1
N
L3
L2
6 mm² max
3N ac
230/400 V 50 Hz
The electrical installation must be installed in
accordance with all relevant British Standards/
Codes of Practice, BS 7671. Or with the relevant
national and local regulations and with the
local gas and electricity supply companies'
requirements.
All installations must be in accordance with the
relevant instructions in this booklet.
n
6 mm² max
Note: The cooker must be connected to the
correct electrical supply as stated on the
voltage label on the cooker, through a suitable
cooker control unit incorporating a double-pole
switch, having a contact separation of at least
3 mm in all poles.
n
6 mm² max
Access to the mains terminal is gained by
removing the electrical terminal cover box on
10 mm² max
the back panel. Connect the mains cable to the
correct terminals for your electrical supply type
(Fig. 1.1 and Fig. 1.2). Check that the links are
correctly fitted and that the terminal screws are
tight. Secure the mains cable using the cable
clamp.
Minimum temperature rating T105.
Read the instructions before installing or using
this appliance.
2
WARNING: THE APPLIANCE MUST
BE EARTHED.
The cooker MUST NOT be connected to
an ordinary domestic power point.
This appliance is heavy so take care when
moving it.
The cable size and type should be suitable
for the Electrical Load of the appliance
and comply with the local requirements
as defined in the latest editions of BS 7671
and or BS EN 50565-1 Reference B4.
The cable must be rated to a minimum of
70 º C
Set the clock to make sure that the oven is
functional – see the relevant section in this
manual.