Graco PR-X Setup - Operation - Repair page 33

Fixed ratio system
Table of Contents

Advertisement

Setup Screen 3 - Bead
F
. 24 Bead Setup Screen (Preset value)
IG
F
. 25 Bead Setup Screen (Custom setting)
IG
On the Bead Setup Screen, press 'F1' or select the
button to display the System Main Screen. Press 'F2' or
select the
button to return to the previous screen.
Press 'F4' or select the
next screen.
There are two Rate command types:
Preset value: The flow rate is defined on Setup
Screen 2 - Shot, see page 32. 'Shot bit 0-3' signals
or style numbers are used to select flow rate.
Custom setting: The operator should set 'Max Rate'
first. The Operator can use 0-10 V signal to control
flow rate.
3A7526B
button to continue to the
HMI Display Operation and Identification
Setup Screen 4 - Sequence
F
. 26 Sequence Setup Screen
IG
On the Sequence Setup Screen, press 'F1' or select the
button to display the System Main Screen. Press
'F2' or select the
button to return to the previous
screen. Press 'F4' or select the
the next screen.
Sequence includes 16 steps maximum. Step 0 and step
15 are used to start job (Pre-charge) and end job
(Depressurization). Operator can select functions
including shot, bead, reload and none. If the shot or
bead function is selected, repeat time can be set (1-99).
button to continue to
33