46
en | Connection
12
Connection
Caution!
Compliance with EN50130-4 Alarm Standard – CCTV for Security Applications
To meet the requirements of the EN50130-4 Alarm Standard, an ancillary uninterruptable
!
power (UPS) supply is necessary. The UPS must have a Transfer Time between 2–6 ms and a
Backup Runtime of greater than 5 seconds for the power level as specified on the product
datasheet.
Note: Consult the National Electrical Code (NEC) or other regional standards for cable
bundling requirements and limitations.
4
Label ID
AC24V
AC24V
EARTH
4
2
1
1
Figure 12.1: AUTODOME IP System Configuration
4
Label ID
ALARM_COM
ALARM_OUT
2021-02-19 | 0.7 |
Connect the cable to the 24 VAC wires from the camera.
Description
24 VAC
24 VAC
Earth Ground
Connect the Ethernet cable to the RJ45 connector of the camera. The following figure
illustrates a typical system configuration.
3
2
1 AUTODOME camera
2 IP connection (Ethernet/Cat5) (100 m maximum)
3 Network switch
4 Network device (computer with monitor, DVR/NVR, etc.)
If desired, connect the alarm and/or audio wires as identified in the following table.
Description
Alarm Communications Red
Alarm Out
Cable Wire Color
Red
Black
Yellow/Green
2
Cable Wire Color
Brown
Installation Manual
AUTODOME IP starlight 5100i IR
4
4
Bosch Security Systems