A/C INSTALLATION
CONDENSED WATER DRAINAGE
DRAIN WATER
T o achieve maximum cooling efficiency, the airconditioner is
designed to splash the condensation water on the condenser
coil.
In order to avoid the splashing sound, an external drain can be
provided by using the following procedure. This may however
cause a small loss of performance.
1. Slide out the chassis from the cabinet.
2. Remove the rubber plug from the body base plate.
3. Install the Drain Pan at corner of the Cabinet with single
screw.
4. Connect the drain hose to the outlet on the bottom of the
drain pan.
5. Slide the chassis into its original place in the cabinet.
1
Slide out the chassis from the cabinet.
Remove the rubber plug from the body
base plate.
2
Screw
Drain Pan
Install the drain pan at the right corner
of the cabinet using 1 screw.
NOISE CONSIDERATION
Select an installation location that can support the weight of the air
conditioner and one that will not cause increased operating noise
and vibration.
Ensure that airflow and noise from the rear side of the unit
(outdoor) when installed do not disturb neighbouring residents.
Obstacles placed in front of the air outlet on the rear side of the unit
(outdoor), or covers placed over it will cause excessive noise and
deterioration in performance.
TRANSFERRING
Repositioning or transfer of the air conditioner due to renovation or moving requires an
additional service charge, Please consult your dealer before moving.
Screw
3
4
Slide the chassis back into the cabinet.
Lock the chassis to the cabinet. Then
reinstall the cabinet to the chassis.
-: 10 :-
Drain Pan
Internal View
Drain Hose
External View