Ccd White Defect Compensation And Check; Ccd Black Defect Compensation And Check - Sony MVC-CD200 Service Manual

Digital still camera
Hide thumbs Also See for MVC-CD200:
Table of Contents

Advertisement

14. CCD White Defect Compensation and Check

Mode
Still (Auto (
Subject
Arbitrary
Measurement Point
Display data of page 6, address: 55
Adjustment Page
7
Adjustment Address
88 to A3
Specified Value1
00 to 7F
Specified Value2
00
Note1: This adjustment should be carried out upon completion of "Data
Setting during Camera System Adjustments".
Note2: Turn on the camera power supply, wait for several minutes, then
perform this adjustment.
Note3: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Adjusting method:
Order Page Address Data
1
0
01
01
2
F
DE
3
F
DE
1E
4
F
E3
5
F
E3
0E
6
6
01
8B
7
6
02
8
6
55
9
6
01
00
10
F
DE
0F
11
F
E3
60
12
6
01
87
13
6
02
14
6
55
Note4: The adjustment data will be automatically input to page: F, address:
88 to A3.
Processing after Completing Adjustments:
Order Page Address Data
1
6
01
00
2
F
DE
3
F
E3
4
0
01
00
RadarW
RadarW
RadarW
RadarW
RadarW
))
Procedure
Set the data.
Write down the data.
Set the data, and press PAUSE
button.
Write down the data.
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note4)
Check that the display data
satisfies the specified value1.
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note4)
Check that the display data
satisfies the specified value2.
Procedure
Set the data, and press PAUSE
button.
Set the data that is written down
at step2, and press PAUSE button.
Set the data that is written down
at step4, and press PAUSE button.
Set the data.

15. CCD Black Defect Compensation and Check

Mode
Subject
Measurement Point
Adjustment Page
Adjustment Address
Specified Value1
Specified Value2
Note1: This adjustment should be carried out upon completion of "Data
Setting during Camera System Adjustments".
Note2: Check that there are no dust, no dirt and no reflection on the clear chart.
Note3: Any subject other than the clear chart should not be in the screen.
Note4: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
ZOOM .................................................................... WIDE end
FOCUS ............................................................ Manual (0.3m)
Adjusting method:
Order Page Address Data
1
0
01
2
F
DF
3
F
DF
4
6
2C
5
6
90
6
6
91
7
6
92
8
6
93
9
6
01
10
6
30
11
6
07
12
13
6
01
14
6
02
15
6
55
16
6
01
17
F
DF
18
6
01
19
6
02
20
6
55
Note5: The adjustment data will be automatically input to page: F, address:
60 to 87.
Processing after Completing Adjustments:
Order Page Address Data
1
6
01
2
6
2C
3
6
91
4
6
30
5
F
DF
6
0
01
5-22
Still (Auto (
))
Clear chart (Color bar standard picture
frame) (Note2)
Display data of page 6, address: 55
7
60 to 87
00 to 0A
00
Procedure
01
Set the data.
Write down the data.
4C
Set the data, and press PAUSE button.
01
Set the data.
00
Set the data.
03
Set the data.
00
Set the data.
00
Set the data.
79
Set the data, and press PAUSE button.
01
Set the data.
Check that the data changes to "01".
Wait for 4 sec.
8D
Set the data, and press PAUSE button.
Check that the data changes to
"01". (Note5)
Check that the display data
satisfies the specified value1.
00
Set the data, and press PAUSE button.
5A
Set the data, and press PAUSE button.
89
Set the data, and press PAUSE button.
Check that the data changes to
"01". (Note5)
Check that the display data
satisfies the specified value2.
Procedure
00
Set the data, and press PAUSE button.
00
Set the data.
00
Set the data.
00
Set the data.
Set the data that is written down
at step2 of "Adjusting method",
and press PAUSE button.
00
Set the data.
RadarW
RadarW
RadarW
RadarW
RadarW

Advertisement

Table of Contents
loading

This manual is also suitable for: