2-7. STROBOSCOPE SECTION (FLASH UNIT)

Note:
The charging capacitor is charged to the maximum of 300V.
There is a danger of electric shock due to the high voltage when the capacitor is touched by bare hand.
Discharge the voltage remained in the capacitor, referring to the Service Note (See page 5).
3 Discharging the capacitor
Short jig
Capacitor
4 Sheet (UW)
1 Capacitor cap
-
2 Capacitor
S Y
6 7
-
J K
8
2 0
[FLASH UNIT SERVICE POSITION]
(CD300)
CD-334 board
-
C D
4
3 3
Lens block assembly
(CD200)
CD-333 board
-
C D
3
3 3
Lens block assembly
Capacitor cap
5 Control switch block
(ZK-503) (14P)
M D
-
0 8
3
Control switch block
(RL-503) (6P)
S Y
6 7
-
J K
8
2 0
FP-364 flexible
board (70P)
3 Stroboscope
base
1 ST sensor
lever
1 Precision screw
(DIA 1.7 × 4)
-
M D
S Y
-
0 8
6 7
-
3
J K
8
2 0
AC power
adaptor
Control switch block
(ZK-503) (14P)
-
M D
-
0 8
3
2-7
4 Two precision
screws
(DIA 1.7 × 4)
6 Stroboscope
cover
7 Flash unit
5 Stroboscope
case assembly
2 ST-POP-UP
spring
A
2 Remove the stroboscope
section in the direction
of the arrow A.
AC IN
Flash unit
Stroboscope case assembly
Stroboscope base, ST sensor lever,
ST-POP-UP spring
CPC-9 jig
1
(J-6082-393-C)
18
Adjustment remote
commander (RM-95)