13. CCD Defect Compensation

Subject
Clear chart
(40 cm from the front of the lens)
Adjustment Page
E
Adjustment Address
C2 to D5
Note 1: Check that there are no dust, no dirt and no reflection on the clear
chart.
Note 2: Any subject other than the clear chart should not be in the screen.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Check that the data of page: E, address: C2 to D5 is "00". If
not, change the data to "00", and press the PAUSE button.
3)
Turn the power of the unit OFF and then ON.
4)
Wait until the camera picture appear on the LCD screen.
5)
Select page: 0, address: 01, and set data: 01.
6)
Select page: E, address: 11, set data: 56, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: E, address: C0, set data: 14, and press the PAUSE
button.
8)
Select page: 2, address: 01, set data: 8D, and press the PAUSE
button.
(When the compensation data is take in, the data will be
automatically input to page: F, address: C2 to D5.)
9)
Select page: 2, address: 02, and check that the data is "01".
Processing after Completing Adjustments
1)
Select page: E, address: 11, set data: 18, and press the PAUSE
button.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 2, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.

14. CCD Defect Compensation Check

Subject
Measurement Point
Measuring Instrument
Specified Value
Note 1: Check that there are no dust, no dirt and no reflection on the clear
chart.
Note 2: Any subject other than the clear chart should not be in the screen.
Note 3: This adjustment should be carried out upon completion of "13.
CCD Defect Compensation".
Adjusting method:
1)
Turn the power of the unit OFF and then ON.
2)
Wait until the camera picture appear on the LCD screen.
3)
Select page: 0, address: 01, and set data: 01.
4)
Select page: E, address: 11, set data: 56, and press the PAUSE
button of the adjustment remote commander.
5)
Select page: 3, address: FA, and set data: 45.
6)
Select page: 2, address: 01, set data: 89, and press the PAUSE
button.
7)
Select page: 3, address: 4C, and check that the data changed to
"01".
8)
Select page: 3, address: FF, and check that the data is "00".
Note: If the data of page: 3, address: FF is "01" to "0F", the CCD
defect compensation is defective.
Processing after Completing Adjustments
1)
Select page: E, address: 11, set data: 18, and press the PAUSE
button.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 2, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
5-17
Clear chart
(40 cm from the front of the lens)
Display data of page : 3, address : FF
Adjustment remote commander
00