UPPER MAIN HARNESS INSTALLATION (4 OF 6)
13
Dress Ground wire from F-Pin Cable (p/n:1-829-088-11), fan
power leads (red/white), and lamp door sensor leads
(grey/white) in M4 wire holder with one loop.
15
Using 2 pieces of 20x50mm himelon tape, overlap
around 10mm to create one long piece.
KF-E42A10/E50A10
14
Install 20x50mm himelon tape on top of duct cover. Use circular
molding mark to center tape horizontally. Use edge of duct cover
for vertical alignment.
Tape p/n:4-079-129-21
16
Install Clamp-On ferrite core to all cables (except
ballast power cables) on top of duct block.
Ferrite core: TDK ZCAT2032-0930; p/n:1-543-830-11
KF-E42A10/E50A10
Tool / Torque
-Phillips Screw Driver
-[4x16mm screw]
-13kg*cm +-1.0kg*cm
Caution Points
Please Follow All
CAUTION
points listed. It
is important to control
VARIATION of wire
routing for minimizing
Electro Maagnetic
Interference (EMI)
68