OVERALL ASSEMBLY (2 OF 3)
5
CAUTION: Make sure Clamp-on Ferrite core is
closed/locked. Make sure wires are not pinched in
between halves of the ferrite core (main reason why
ferrite will not lock easily).
7
Dress AC Cord (above the Ferrite core) with M3 clamp
installed on Terminal Bracket, and insert AC Grommet in slot
on the Terminal Bracket.
KF-E42A10/E50A10
6
Connect CN8814(6P), CN8004(40P), and CN8400(6P) on AGA-Bd. Route
cables along stacking boss.
Dress
lighning ground cables
(p/n:1-910-015-17) in tall purselock (p/n:4-
077-726-11). Twist purselock to close it.
8
CAUTION: Make sure AC cable is dressed to the LEFT of the Lightning
Ground Wires (underneath wires). If AC cables are routed OVER the
Lightning Ground Wires, the AC cable will push on the Lightning Ground
Wires when the ferrite core on the AC cord is dressed in the M3 Clamp
(on Terminal Bracket). This pressure on the Lightning Ground Wires can
cause the terminals to bend/break and dislocate from GTA-PWB.
KF-E42A10/E50A10
Tool / Torque
-Phillips Screw Driver
-[3x12mm]
-7kg-cm +-0.5kg-cm
-[3x8mm]
- 5kg-cm +-0.5kg-cm
Caution Points
Please Follow All
CAUTION
points listed. It
is important to control
VARIATION of wire
routing for minimizing
Electro Maagnetic
Interference (EMI)