Standby Operation Guidelines

For safe, reliable operation in Standby mode, it is important to
follow a few guidelines:
Always check that the unit is OFF by pressing OFF key
on controller before connecting or disconnecting the
unit from the power source.
The circuit breaker and power cord used for Standby
operation must comply with legislations currently
applicable for site of use and with unit specifications in
table below.
Unit
35X
40X
50X
When multiple units are in use, each unit must be operated on
its own electrical circuit. You should never operate more than
one unit on a circuit breaker.
Important note: The above information is provided as a guideline
only. When preparing a circuit for operation of the refrigeration unit,
a licensed electrician should be contracted. A licensed electrician
is familiar with all local ordinances and special requirements for
your area and can ensure that the circuits are properly designed,
installed, and connections are correct.
Operating Voltage
115/1/60
230/1/60
230/3/60
230/1/60
230/3/60
230/1/60
230/3/60
Operating Amperage
23
Maximum Unit
23.2 A
11.2 A
8.9 A
24 A
14 A
25 A
15 A