OCTO
ways overwrite the previously saved data, so the file always contains only the most
recent data set. Select "Automatic data export" below the "Data log" headline in
the listing to access the settings screen. Create a new export data set by clicking
the plus symbol in the upper right corner of the screen. Enter name, path and time
interval to meet your requirements. You may then add the data sources to log by
clicking the plus symbol in the "Data sources" window section. You may add an
unlimited number of data sources to each export data set, the total number of ex-
port data sets is also unlimited.
9. 9. 9. 9. Sensor configuration
Sensor configuration
Sensor configuration
Sensor configuration
Select "Sensors" from the device list below the "OCTO" entry. In the up-
per area, the twenty-one available sensors are displayed including current
data. In the lower area, the currently selected sensor can be configured.
9.1.
9.1. Hardware temperature sensor
Hardware temperature sensor
9.1.
9.1.
Hardware temperature sensor
Hardware temperature sensor
The first four sensors in the list represent the temperature sensor inputs of the
OCTO.
If necessary, each temperature sensor can be calibrated by adding an offset of
±15 °C.
9.2. Hardware flow sensor
9.2.
9.2.
9.2.
Hardware flow sensor
Hardware flow sensor
Hardware flow sensor
The fifth sensor in the list represents the flow sensor input of the OCTO. Calibra-
tion values for sensors sold by Aqua Computer can conveniently be selected from
a drop-down list. Select the appropriate entry for the flow sensor connected to the
OCTO.
If necessary, the flow rate can be calibrated by ±10 %.
9.3.
9.3. Software sensors
Software sensors
9.3.
9.3.
Software sensors
Software sensors
The last sixteen sensors in the list are software sensors and can be used to transmit
sensor data that is not physically available to the OCTO controller from the com-
puter by USB connection.
During installation of the aquasuite, the background service "Aqua Computer Ser-
vice" is also installed. This service supplies various data from PC components and
imported data from aquasuite web, additionally sensor data provided by third par-
ty software can be accessed. In order to access third party software data, the third
party software has to be correctly installed, configured and running.
Currently, the "Aqua Computer Service" supports data transfer from "HWiNFO"
(REALiX, Freeware, www.hwinfo.com) and "AIDA64" (FinalWire Ltd., subject to li-
cense fees, www.aida64.com).