Aqua Computer poweradjust 3 User And Installation Manual

Aqua Computer poweradjust 3 User And Installation Manual

Usb unit is a high power fan or pump controller for pcs

Advertisement

aqua
computer
User and installation manual
User and installation manual
User and installation manual
User and installation manual
All information contained in this manual is subject to change without prior notice.
All rights reserved.
© 2014-2016
poweradjust 3 USB
poweradjust 3 USB
poweradjust 3 USB
poweradjust 3 USB
Firmware version 1006
aquasuite version 2016
Current as of October 2016
Aqua Computer GmbH & Co. KG
Gelliehäuser Str. 1, 37130 Gleichen
POWERADJUST 3
- 1 -

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the poweradjust 3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Aqua Computer poweradjust 3

  • Page 1 2016 Current as of October 2016 All information contained in this manual is subject to change without prior notice. All rights reserved. © 2014-2016 Aqua Computer GmbH & Co. KG - 1 - Gelliehäuser Str. 1, 37130 Gleichen...
  • Page 2: Table Of Contents

    9.1. Fan mode..................13 9.2. Manual fan settings..............14 9.3. Speed settings................14 9.4. Automatic temperature control.............14 9.5. Start boost and output settings............14 10. Alarm configuration(aquasuite)..........14 10.1. Speed signal/Output..............14 - 2 - Aqua Computer GmbH & Co. KG © 2014-2016 Gelliehäuser Str. 1, 37130 Gleichen...
  • Page 3 POWERADJUST 3 10.2. Alarm reporting and alarm limits..........15 11. System settings poweradjust 3 (aquasuite)........15 11.1. Device information..............15 11.2. Factory defaults................15 11.3. Key management..............15 11.4. Current measurement calibration..........16 11.5. aquabus configuration..............16 11.6. External temperature sensor............16 11.7. Flow sensor................16 12. Basic settings (aquasuite)............16 12.1.
  • Page 4: Preface

    1. Preface 1. Preface The poweradjust 3 USB unit is a high power fan or pump controller for PCs. The output features speed signal detection, additionally the poweradjust 3 USB unit has a temperature sensor input, a flow sensor input, a speed signal output as well as USB and aquabus interfaces.
  • Page 5: Electrical Connections

    V is 2.5 A (30 Watts total power), with optional heat sink (not included in delivery) 3.0 A / 36 Watts. The poweradjust 3 features temperature monitoring to prevent damage to the poweradjust 3 controller board. If the internal electronics tempera- ture sensor reading exceeds approximately 80 °C, the power output is set to 100...
  • Page 6: Usb

    5.5. aquabus 1/2 Connector for communication with other Aqua Computer devices. You can use the aquabus/speed signal cable included in delivery to connect the poweradjust 3 controller board to a suitable connector of a compatible device, for example an aquaero. USB and aquabus interface can be used at the same time, aquabus data is processed with higher priority.
  • Page 7: Speed Signal

    USB or aquabus connection (providing that power is supplied to the de- vice). Please note: Depending on the type of product you are using, some features may not be available for your device. © 2014-2016 Aqua Computer GmbH & Co. KG - 7 - Gelliehäuser Str. 1, 37130 Gleichen...
  • Page 8: Installation Of The Aquasuite Software

    6.1. Installation of the aquasuite software 6.1. Installation of the aquasuite software For configuration and monitoring of poweradjust 3 USB units, the aquasuite soft- ware is available for download from our website www.aqua-computer.de. You will find the most up-to-date version in the support section of the website.
  • Page 9: Overview Pages (Aquasuite)

    Please note that individ- ual values can be selected as © 2014-2016 Aqua Computer GmbH & Co. KG - 9 - Gelliehäuser Str. 1, 37130 Gleichen...
  • Page 10: Editing Existing Elements

    You may want to customize the code. By clocking the “Ok” Button, the new control is saved to the overview page. - 10 - Aqua Computer GmbH & Co. KG © 2014-2016 Gelliehäuser Str. 1, 37130 Gleichen...
  • Page 11: Log Data Chart

    8. Data log (aquasuite) 8. Data log (aquasuite) 8. Data log (aquasuite) Data from all connected Aqua Computer devices can be logged by the aquasuite. Logged data can then be analyzed by creating charts or be exported to files. © 2014-2016 Aqua Computer GmbH &...
  • Page 12: Log Settings

    You may also drag the little circle beside the text box to move the connecting line to the desired position. Use drag and drop to move existing annotations. - 12 - Aqua Computer GmbH & Co. KG © 2014-2016 Gelliehäuser Str. 1, 37130 Gleichen...
  • Page 13: Manual Data Export

    9.1. Fan mode In the upper area, current fan data (speed, power output, voltage) is displayed as plain text as well as in a diagram. © 2014-2016 Aqua Computer GmbH & Co. KG - 13 - Gelliehäuser Str. 1, 37130 Gleichen...
  • Page 14: Manual Fan Settings

    The start boost feature can be used to reliably power up a fan or pump connected to the power output. If activated, the poweradjust 3 unit will set the output to the configured power for the configured duration before switching to normal opera- tion.
  • Page 15: Alarm Reporting And Alarm Limits

    11.3. Key management 11.3. Key management In order to upgrade your poweradjust 3 unit to a higher version, you will need the serial number and the device key from the “Device information” section of this page. Order the desired upgrade from the Aqua Computer web shop and enter serial number and device key into the “Annotations”...
  • Page 16: Current Measurement Calibration

    11.7. Flow sensor 11.7. Flow sensor If a flow sensor is connected to the poweradjust 3 unit, set up the flow sensor input in the lower region of the screen. The current sensor reading is displayed as well. 12. Basic settings (aquasuite) 12.
  • Page 17: Service Administration

    12.4. Service administration 12.4. Service administration The service (background service) configures special USB settings for all connected Aqua Computer devices and should therefore always be active. 13. Technical details and care instructions 13. Technical details and care instructions 13. Technical details and care instructions 13.
  • Page 18 POWERADJUST 3 - 18 - Aqua Computer GmbH & Co. KG © 2014-2016 Gelliehäuser Str. 1, 37130 Gleichen...
  • Page 19 POWERADJUST 3 © 2014-2016 Aqua Computer GmbH & Co. KG - 19 - Gelliehäuser Str. 1, 37130 Gleichen...
  • Page 20 POWERADJUST 3 94409 - 20 - Aqua Computer GmbH & Co. KG © 2014-2016 Gelliehäuser Str. 1, 37130 Gleichen...

Table of Contents