1. CONTENT 2. SYMBOLS AND MARKING 3. SAFETY INSTRUCTIONS AND PRECAUTIONS 4. INFORMATION ABOUT THE PRODUCT 4.1. DESCRIPTION 4.2. DIMENSIONS AND WEIGHT 4.3. TECHNICAL DATA 4.4. OPERATING CONDITIONS 4.5. STANDART PACKAGE OF COMPONENTS 4.6. DESCRIPTION OF COMPONENTS 5. INSTALATION 5.1. RECEPTION OF GOODS 5.2.
2. SYMBOLS AND MARKING Warning – pay attention Additional information Apply the auxiliary label on the unit (on an easily accessible location) or on the dashed location of the technical manual in order to keep the im- portant information about the unit. Figure.
Salda Antifrost the air in from the room and the duct-exhaust gases out through chimney or extraction ducting. The heating appliance can be starved protection (see Salda Antifrost function in the Remote Controller Operation Manual). | EN SMARTY XP v2020.3...
Product name Control board Type Duct based Air Duct based Air ture control damper Pre-Heater Heater Smarty 2X P 1.1 Mini MCB Premium Smarty 2X P 1.2 Mini MCB Basic Advanced Smarty 3X P 1.1 Mini MCB Premium Smarty 3X P 1.2...
4.4. OPERATING CONDITIONS SMARTY 2X P 3X P 4X P F2 Minimum outdoor air temperature Maximum outdoor air temperature Minimum extracted air temperature Maximum extracted air temperature Maximum extracted air relative humidity Minimum ambient air temperature Maximum ambient air temperature Instillation indoor indoor...
5. INSTALATION 5.1. RECEPTION OF GOODS Each device is carefully checked before transportation. When receiving the goods, checking the devices for any damage made during transporta- tion is recommended. If any damage to the unit is observed, immediately contact the representatives of a transport company. Please inform the representative of the manufacturer, if any deviation of the device is noticed.
• Before commencing the installation of the unit, please check if all ordered equipment have been delivered. Any variation from the ordered equip- ment list must be reported to the product supplier. 5.4. PIPING AND INSTRUMENTATION DIAGRAM Figure 5.4.1. Smarty XP 1.1 (*Exhaust air sensor is not included with a device and should be ordered as an accessory; ** Check the manual for details;...
POSIBLE PCB INPUTS/OUTPUTS Fire alarm Fireplace protection Working indication output Alarm indication output 5.5. MOUNTING • • When connecting air ducts, consider the labels on the casing of the unit. • Before connecting to the air duct system, the connection openings of ventilation unit should be closed. •...
5.7. CEILING-MOUNTING OF THE UNIT Ceiling-mounting of the unit ⌀ 5.8. CONNECTION OF THE AIR DUCT D or Da dimensions depend on unit. SMARTY XP v2020.3 EN |...
and noise level, you can increase the diameter. • In order to reduce the level of the noise in the air supply system, install dampers (see the chapter on air supply system installation). • External air and exhaust system piping should be isolated in order to prevent heat loss and condensation. •...
6. MAINTENANCE 6.1. SAFETY INSTRUCTION Unplug the unit from the mains before opening the door (disconnect the power plug from the outlet or in case a two-pole au- 6.2. GENERAL RECOMMENDATIONS FOR THE MAINTENANCE OF VENTILATION SYSTEM COMPONENT DURING START-UP AT LEAST EVERY 6 MONTHS Filters device indications.
Smarty 3XP/4XP F2 6.4. FILTERS MAINTENANCE • • manual or on our website www.salda.lt 6.5. HEAT EXCHANGER MAINTENANCE • Proceed to maintenance and repair every time the fan rotation is stopped. Clean the heat exchanger once per year. • Smarty 2X P | EN SMARTY XP v2020.3...
Smarty 3XP/4XP F2 6.6. FAN MAINTENANCE • • The fan should be inspected and cleaned at least once per year. • • The fans features a heavy-duty ball bearing design. The motor is completely sealed and free of maintenance. • Detach the fan from the unit. •...
Smarty 3XP/4XP F2 6.7. BYPASS DAMPERS MAINTENANCE • Bypass damper must be disconnected from automation panel (connections X3 and X5). • When removing the damper, steps A1 (1-3), B1 (1-3), C1 (1-3) should be performed for Smarty 2X P, and steps A2, B2 (1-3), C2 (1-2) for Smarty 3-4X P.
6.8. CONTROL BOARD MAINTENANCE • • Disconnect the connectors from control board . Disconnect hoses from pressure sensors (Smarty 3XP/4XP F2 1.1). • Remove the control board through the front part of the device. • The connectors are marked according to connection location. Thus during control board installation please observe the marking of the con- Smarty 2X P Smarty 3XP/4XP F2 SMARTY XP v2020.3...
SALDA AIR mobile application ST-SA-Control BMS over Modbus TCP/IP BMS over BACnet TCP/IP 7.2. DEVICE FUNCTIONS application and SALDA AIR mobile application. For unit control instructions, refer to the operation manual of the existing control device. | EN SMARTY XP v2020.3...
Page 22
EKA NIS connection: | EN SMARTY XP v2020.3...
Page 23
8.1.1.2. VERSION 1.2. Smarty XP 1.2. units feature one connection of external electrical heater/pre-heater. In factory settings, the connection is intended for the pre-heat- • 0-10V – EKA NIS EKA connection: SMARTY XP v2020.3 EN |...
Page 24
EKA NIS connection: | EN SMARTY XP v2020.3...
Page 25
WEB application service or on the ST-SA-Control panel. Settings in the environment of the MB-Gateway WEB application service • Service > Heaters > Heater and pre-heater position; For the Stouch control panel, changing of the settings is not possible • Service > Digital inputs > Heater protection inputs Set the manual and automatic protection device modes of the heater or pre-heater (NC by default).
Page 26
• Service > Heaters > Supply air heater or outdoor air pre-heater Settings with the ST-SA-Control panel 2. Select Control Position as 'Heater on basic' or 'Pre-heater on basic. 3. Go to Menu/Service/Heaters/Heaters and set the heater type 0.10VDC – 0-10 control, system response protection signal.
8.1.2. Automation controller A zone X4 8.1.3. EXTERNAL CO /RH SENSORS Smarty XP 1.1. /RH (input 0-10VDC) sensors. Sensors connection: Smarty XP 1.2. units feature one connection for external CO /RH (input 0-10VDC) sensors. Sensors connection: These sensors feature 3 functions: Supply RH, Extract RH and Extract CO Supply RH transmitter shall be installed inside supply air duct.
8.1.4. ROOM CO TRANSMITTER INSTALLATION RECOMMENDATION 5 0 c m i n . min. 60 cm max. 400m If the duct CO transmitter is used, it must be installed in the extract air duct. To install duct transmitters, hole drilling tools are required .
8.1.7. CONNECTION OF REMOTE CONTROL PANEL OR MODBUS Wiring diagram. Automation controller F zone, X18 connector. Switch Position Purpose 8.1.8. Wiring diagram. Automation controller C zone, X23 connector. LED INDICATION miniMCB miniEX1 LED1 LED1 EX1 status LED LED2 LED3 LED4 MiniMCB status LED LED5 Communication line Transmit indication...
8.1.9. RECOMMENDED SCHEME FOR CONNECTION OF INTERNAL AND EXTERNAL COMPONENTS *Only Smarty 1.1 versions have N2 module. Figure 8.1.9.1. | EN SMARTY XP v2020.3...
9. POSSIBLE FAULTS AND TROUBLESHOOTING FAILURE CAUSE EXPLANATION / CORRECTIVE ACTIONS No supply voltage Unit is not operating leakage relay is active (if installed by the installer) matic protection Check if fans are rotating Air supply heater or pre-heater is not operat- ing or malfunctioning (if installed) Manual safety device is activated MUST be contacted to identify and eliminate...
10. ECODESIGN DATA TABLE MODEL SMARTY 2XP 1.1 consumption SEC Class Climate Control Control typology zone factor [ kWh/m²/a ] [ kWh/a ] [ kWh/a ] Clock control (standard) 0,95 -35,1 4486 Average 0,85 -37,4 4530 0,65 -41,4 4617 Clock control (standard) 0,95 -72,6 8776...
Page 37
MODEL SMARTY 2XP 1.2 consumption SEC Class Climate Control Control typology zone factor [ kWh/m²/a ] [ kWh/a ] [ kWh/a ] Clock control (standard) 0,95 -35,1 4486 Average 0,85 -37,4 4530 Clock control (standard) 0,95 -72,6 8776 Cold 0,85 -75,3 8861 Clock control (standard)
Page 38
MODEL SMARTY 3XP 1.1 consumption SEC Class Climate Control Control typology zone factor [ kWh/m²/a ] [ kWh/a ] [ kWh/a ] Clock control (standard) 0,95 -36,1 4447 Average 0,85 -38,2 4494 0,65 -41,7 4590 Clock control (standard) 0,95 -73,3 8699 Cold 0,85...
Page 39
MODEL SMARTY 4XP F2 1.1 consumption SEC Class Climate Control Control typology zone factor [ kWh/m²/a ] [ kWh/a ] [ kWh/a ] Clock control (standard) 0,95 -33,0 4389 Average 0,85 -35,6 4443 0,65 -40,1 4551 Clock control (standard) 0,95 -69,6 1001 8586...
11. DECLARATION OF CONFIMITY Manufacturer SALDA, UAB LT-78109 Šiauliai, Lithuania Tel.: +370 41 540415 www.salda.lt Smarty XP* Machinery Directive 2006/42/EC EMC Directive 2014/30/EU Low Voltage Directive 2014/35/EU Ecodesign Directive 2009/125/EC RoHS 2 Directive 2011/65/EU Ecodesign requirements for ventilation units Nr. 1253/2014 Energy labeling of residential units Nr.
12. WARRANTY date. such damage. damaged by installing the control system. 4.1. mechanical damage; 4.2. damage caused by entering outside objects, materials, liquids; lation and mounting regulations, deliberate or careless users or third-party behavior. days and deliver the equipment to manufacturer. Delivery costs should be covered by customer. Manufacturer reserves the right to change this technical passport any time without prior notice, if some typographic errors or inaccurate information is found, as well as after improving the apps and/or the devices.
Page 44
Once per year** Every 3-4 Filter replacement months** Look at the product label. ** - At least. NOTE. The customer shall be required to complete the Product Maintenance Table. MANUALS IN OTHER LANGUAGES https://select.salda.lt/file/ https://select.salda.lt/file/ https://select.salda.lt/file/ https://select.salda.lt/file/ https://select.salda.lt/file/ smartyxpde smartyxpdk smartyxpfr smartyxplt smartyxpnl https://select.salda.lt/file/...