Section 9: Maintenance and Storage
The service life of your FallTech Web SRL will depend on two factors: The environmental
conditions of your working environment along with proper care (specifically,
maintenance and storage).
Keeping the SRL clean and free of contaminants will greatly increase the service life
and will ensure that the SRL will be in proper working order in the event that you need it
to arrest a fall. The following steps should be taken periodically:
1. Using a damp rag and a mild soap and water solution, wipe down the SRL housing
to remove soil and surface contaminants. Ensure that the labels are legible at all
times.
2. Use a slightly damp rag and a mild soap and water solution to clean the webbing
element of the SRL. Allow it to air dry.
3. Use a damp rag to clean the surfaces of any connecting hardware.
4. If there is an excessive build up of paint, oil, dirt tar or other contaminants that
cannot be removed, remove the SRL from service and have it replaced.
5. Store in a cool, dry location away from direct sunlight and where it will not be
exposed to chemical vapors.
6. This SRL should be hung on a rack or a peg or stored flat on a shelf, stacked no
more than three high.
7. Do not throw the SRL into a pile or a locker or storage box, as this may damage the
housing.
FallTech Web SRL's do not require recertification . Provided your SRL passes
inspection, has been maintained and is in serviceable condition, there is no need to send
it in. If your SRL is in need of repair or you are concerned about its condition, return it
to the place of purchase to arrange an inspection and/or repair through an authorized
service center. For further details, contact FallTech.
Section 10: Specifications
This section contains important information regarding the performance and
construction of this product. Pease read and be familiar with this and all information
contained in this instruction manual.
10.1: Mandatory Disclosures
Inspection Log
FallTech Contractor Series Cable SRL
Comments
17
Pass/Fail
Corrective
Approved
Action to be
Taken
By
Need help?
Do you have a question about the 7262 and is the answer not in the manual?