2 3 4 5 Trouble Shooting - RadonAway AIRaider 433-S50 Instruction & Installation Manual

All residential & small system models
Table of Contents

Advertisement

1
2
3
4
Symptom
No water in house
System running dry
Water not entering system
Jet Pump not functioning
Pressure in tank is less than 40 PSI
Low water flow at faucets
Loud banging when solenoids shut
Solenoids chatter when closing
Blower not running
Blower does not stop running
Pump is short cycling
Pump won't shut off
IN063 Rev.D 0120
TROUBLE SHOOTING
5
Solution
• Check power: Switch in on position, circuit breaker at panel in on
position, fuses in control panel intact.
• Check pressure in tank. If below the proper settings, reset the pump
as described in System Start-up (p. 17).
• Bypass System. If there is still no water, main well pump may not
be functioning.
• Check on/off float for proper operation. Replace if necessary.
• Check sediment strainer and/or filter (if applicable) and clean if necessary.
• Install a flow restrictor or meter down the ball valve until the AIRaider
outflow is 1 GPM or more less than the water flow entering the system.
• Check solenoids for proper operation. Replace if necessary.
• Check float switches for proper operation. Replace if necessary.
• Check sediment strainer and/or filter (if applicable) and clean if necessary.
• Check fuse in control panel.
• Check breaker at electrical panel.
• Replace jet pump if necessary.
• Reset jet pump as described in System Start-up (p. 17).
• Check bladder tank.
• Replace jet pump and/or bladder tank as necessary.
• Clear sediment strainers on faucets.
• Clear pump inlet screen/water injector.
• Replace pump if necessary.
• Install water hammer suppressor or loop of flexible hose in pump inlet line.
• Shorten the length of pipe between the well pressure tank and the system.
• Check On/Off float for proper operation. Replace if necessary.
• Check fuses in control panel.
• Replace timer if necessary.
• Replace blower if necessary.
• Check On/Off float for proper operation.
• Check Timer Settings.
• Replace Timer Relay if necessary.
• Bladder tank may be ruptured. Replace if necessary.
• Check pressure switch on pump for proper operation.
• Call for support.
3 Saber Way, Ward Hill, MA 01835 | radonaway.com
TM
Page 20 of 22

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Airaider 433Airaider 433-1Airaider 321

Table of Contents