Thermo Scientific Fisherbrand GT4 Instruction Manual page 26

Table of Contents

Advertisement

Failure
Problem with centrifuge
message
E-25-E-27
The centrifuge cannot be
operated.
The run does not start or the
centrifuge runs down without
being braked.
E-28
The centrifuge cannot be
operated.
The run does not start or the
centrifuge runs down without
being braked.
E-29
The centrifuge cannot be
operated.
The run does not start.
E-30
The centrifuge cannot be
operated.
The run does not start or the
centrifuge runs down without
being braked.
E-33
The centrifuge cannot be
operated.
The run does not start or the
centrifuge runs down without
being braked.
E-34-E-36
The centrifuge cannot be
operated.
The run does not start or the
centrifuge runs down without
being braked.
E-40
The centrifuge cannot be
operated.
The run does not start or the
centrifuge runs down without
being braked.
E-41-E-74
The centrifuge cannot be
operated.
The run does not start or the
centrifuge runs down without
being braked.
22 |
Troubleshooting
Possible causes and cures
Time has expired for the lid lock drive while opening the lid.
Restart the centrifuge.
If an error message appears again, contact Unity Lab Services.
Error during the self-test of the centrifuge program and the
electronics.
Restart the centrifuge.
If an error message appears again, contact Unity Lab Services.
Check whether you selected the right bucket.
Is it easy to turn the rotor when the lid is open?
Does the rotor rub against the device?
Restart the centrifuge.
If an error message appears again, contact Unity Lab Services.
Restart the centrifuge.
If an error message appears again, contact Unity Lab Services.
Overpressure in the refrigeration unit.
Clean the air inlet for the condenser.
Restart the centrifuge.
If an error message appears again, contact Unity Lab Services.
Error during the self-test of the centrifuge program and the
electronics.
Restart the centrifuge.
If an error message appears again, contact Unity Lab Services.
The centrifuge accelerates too slowly.
Check whether you selected the right bucket.
Is it easy to turn the rotor when the lid is open?
Does the rotor rub against the device?
Restart the centrifuge.
If an error message appears again, contact Unity Lab Services.
Error during the self-test of the centrifuge program and the
electronics.
Restart the centrifuge.
If an error message appears again, contact Unity Lab Services.
Centrifuge GT 4 / 4R