Displays and address ranges
5.3 Carrier control
LED
ERR
DISP
5.3.2
Address ranges of the PSB-C module
NOTICE
Malfunction
8 bytes are reserved in the I/O address space of the PSB-C module for the EMS400S
function blocks. These 8 bytes are managed by the EMS400S function blocks. You risk
malfunctions if using these 8 bytes for other data.
Do not use the reserved area.
The word and byte addresses specified in the following tables are relative addresses. This
means that they depend on the respective start address.
Input address space
The input address space of the PSB-C module is used to map data that is received from the
plant segment controller and display unit.
36
Display
Meaning
On
The display unit is not connected.
•
Error in communication between the PSB-C module and the display
•
unit
Firmware of the PSB-C module is incompatible with the firmware of the
•
display unit
A firmware update was performed
•
Off
No error in communication between the PSB-C module and the display
unit
Operating Instructions, 03/2014, A5E03474166-03
PSB modules