Displays and address ranges
5.3 Carrier control
The output address space comprises 8 bytes.
Word Byte
0
2
4
6
1
Observe the signal cycle times specified in the section "Data processing plant segment
controller – carrier controller (Page 41)".
5.3
Carrier control
The control unit of the carrier controller comprises an S7-1200 CPU and a PSB-C module.
34
Bit
Name
0, 1
–
Data transmitted to the carrier
controller in plant segment n
2, 3
–
Data transmitted to the carrier
controller in plant segment n + 1
4, 5
–
Data transmitted to the carrier
controller in plant segment n + 2
6
0
Validation bit RAIL 1
1
Validation bit RAIL 2
2
Validation bit RAIL 3
3
Enable bit RAIL 1
4
Enable bit RAIL 2
5
Enable bit RAIL 3
6
Acknowledgment bit RAIL 1
7
Acknowledgment bit RAIL 2
7
0
Acknowledgment bit RAIL 3
1
Reserved
2
Parity bit RAIL 1
3
Parity bit RAIL 2
4
Parity bit RAIL 3
5 ... 7
Reserved
The data word contains user data. This data serves for communication of the plant segment
controller with the carrier controller.
Description
The data has a length of
one word
1
0 = invalid data, or error
1 = valid, current data
0 = disabled
1 = enabled
0 = data not to acknowledge
1 = data to acknowledge
–
0 = Odd rail segment
1 = Even rail segment
–
Operating Instructions, 03/2014, A5E03474166-03
Terminals
RAIL 1
RAIL 2
RAIL 3
RAIL 1
RAIL 2
RAIL 3
RAIL 1
RAIL 2
RAIL 3
RAIL 1
RAIL 2
RAIL 3
–
RAIL 1
RAIL 2
RAIL 3
–
PSB modules