Installation Procedure
FCU installation
CAUTION
Before installing this fax unit:
1) Print out all data in the printer buffer.
2) Turn off the main power switch and disconnect the power cord and
the network cable.
1. Disconnect the ADF connector [A].
2. Remove the rear upper cover [B] (
• Slide down to remove.
• When re-attaching, before tightening the screws make sure that the tabs on
the cover are engaged with the shoulder screws.
3. Remove the rear lower cover [C] (
• When re-attaching, before tightening the screws make sure that the tabs on
the cover are engaged with the shoulder screws.