3. Elimination of the fusing lamp for side heating
The lamp for side heating (listed in the MT-C3 Parts Catalog on pg. 99, item 28) was
eliminated on the MT-C3.5c. This is because the warm-up time on this model (60 sec.) is
30 seconds slower than on the MT-C3 (30 sec.), and as a result, there is no need to
provide additional heat to the roller ends. It has been confirmed that eliminating this lamp
does not affect image quality. This change will make it easier to replace/install fusing
rollers in the field.