1
Compressor
2
Fan
3
Low pressure switch
4
High pressure switch
5
Solar sensor
6
Evaporator sensor
7
External sensor
8
CH boiler sensor
V. CONTROLLER MENU
Tap on the menu icon to view the parameters tabs. The controller offers five tabs, each of them includes up to three functions. In
order to edit a particular parameter, tap on its icon. Tap again to open up editing screen. In order to confirm the settings, tap on
the icon or anywhere on the touch screen:
1.
PARTY MODE
After switching the Party Mode on, the pump's heat tank reaches the pre-set temperature in the fastest possible time. All available
heat sources operate simultaneously in this mode.
2.
HEATER
In this operation mode only the heater is active.
3.
LEGIONELLA MODE
Thermal Disinfection involves increasing the temperature to a necessary disinfection temperature of at least 60°C in the entire
DHW circulation.
New regulations impose the obligation to adjust the tank to periodical thermal disinfection conducted at a water temperature no
lower than 60°C (recommended temperature 70°C). The ducts, fittings and technological system of hot water preparation need
to comply with this condition.
The boiler's disinfection is aimed to eliminate the Legionella Pneumophila bacteria which cause a reduction of the body's cell
immunity. The bacteria often multiply in stagnant hot water tanks (optimum temperature 35°C), which frequently happens, e.g.
in boilers.
After activating the Legionella Mode, the boiler heats up to 70°C (factory setting) and maintains this temperature for 30 minutes
(factory setting) and then comes back into regular operation mode.
From the moment the disinfection is switched on, the temperature of 70°C needs to be reached in no longer than 90 minutes
(factory setting). Otherwise, this function switches off automatically.
Any changes of settings for this function are only possible in the servicing mode.
4.
TIME SETTINGS
By setting the timer, the user defines the current time. Setting the time is necessary for the proper functioning of the Weekly
control.
5.
DATE SETTINGS
By using this function, the user sets the current day of the week. Setting the day of the week is necessary for the proper functioning
of the Weekly control.
9
Control sensor
10
Tank sensor
11
Defrost valve
12
Heater
13
Additional pump
14
Circulating pump
15
Anode
36